WESROC© RMS Satellite Repeater – User Manual
Metrotel Corporation of Minnesota, Inc.
Revision A. May 7, 2008
Page 8
PDU Satellite Repeater Detail Screens
The PDU displays five unique informational status screens for the Satellite
Repeater. Once the first screen has been displayed by pressing the right button
from the transmitter list screen, subsequent screens may be accessed by
pressing the up or down buttons. Each press of the up or down button shows the
previous or next screen respectively.
Satellite Repeater Identification Screen
Screen 1 shows general information about the Satellite Repeater:
1. Satellite Repeater Electronic Serial Number (ESN). This ESN is the
same as the ESN of the Axonn® STX-2 module. It is also the ESN by
which Globalstar® associates Satellite Repeaters with Independent
Technologies.
2. Application Code .(10 for Satellite Repeater).
3. Hardware Type. (Will increase upon hardware changes).
4. Firmware Version. (Will increase upon software changes).
5. System Status Bits.
6. Frequency error of transmission between SatRep and PDU in kHz.
Normally this value should be less than +-10kHz.
7. DC Voltage Supplied to SatRep in milliVolts. This is mostly of concern
when the Satellite Repeater is used with solar power. The Satellite
Repeater will cease normal operations if this value drops below
10.6VDC.
To view the next screen, press the down button.