83
©2004 Metrologic Instruments, Inc. All rights reserved MS2020 Stratos Service Manual
ORDERING PARTS AND GENERAL SERVICING INFORMATION
IMPORTANT SITE INSTALLATION INFORMATION
Before installing your Stratos scanner/scale, please consider the following items!
Vertical Clearance
A minimum clearance height of 7.50" from the check stand surface is needed for the
vertical 'hood' on all of the scanner models. Additional clearance is recommended for
unobstructed LED viewing by the operator.
Ventilation and Spacing
All Stratos models have a die-cast housing to dissipate heat allowing the unit to operate
without a ventilation fan. Metrologic recommends that the temperature surrounding the
unit does not exceed 40°C (104°F). There should be adequate convection and minimal
heat producing equipment in close proximity of the unit.
A cooling fan with a filter is recommended if there will be a conveyor motor or other heat
producing equipment close to the unit that will create a high temperature environment.
Adequate spacing between the unit and the check stand opening is required for proper
operation of the scale. When the scanner/scale model is mounted properly, the scale
platter should be able to move up and down freely without hitting the edges of the check
stand cutout. Refer to
Installing the Unit in the Counter
for detailed cutout dimensions
and mounting instructions.
Service Access
When routing and installing the cable(s) and power supply, make sure you leave access
that these components may be swapped easily without the need to remove the unit from
the check stand.
When changing the StratosSWAP optics engine modules, Metrologic recommends
removing the unit completely from the check stand.
When calibrating or zeroing the scale, do not remove the unit from the check stand.
Refer to the
Scale Operation Section
of this guide
for detailed instructions
on zeroing
and calibration.
Power Installation
The Power Supply (AC/DC) should be connected to an AC Outlet that is free of
electrical noise (clean). A qualified electrician can determine the amount of electrical
noise on the AC line. See additional information on power installation and restrictions
on pages 31 - 45.