38
©2004 Metrologic Instruments, Inc. All rights reserved MS2020 Stratos Service Manual
SERVICING AND MAINTENANCE PROCEDURES
VERTICAL SCAN MODULE – REMOVAL PROCEDURE
Removal Instructions:
1. Remove platter tray and carefully set a
side in a safe location. (Refer to
Removal Instructions located on page
29 of this manual)
2. Remove Stratos Scanner chassis from
counter. (Refer to Removal Instructions
Section.)
3. Carefully turn Stratos Scanner unit
upside-down and locate the 6 TORX
Screws keeping the Vertical Scanner
Module in place. (Refer to Figure to the
right.)
4. Using a size T-10 torx screwdriver,
remove all 6 torx screws noted in step 3.
5. Remove rear plate as shown in picture
to the right.
6. Carefully grip Vertical Scan Module with
both hands around front and rear of
Vertical Scan Module’s metal base
plate.
7. With a gentle pulling motion, pull module
slightly back then begin to lift module
up.
8. Unsnap ZIF connector to remove cable
before module is removed.
9. Place old Vertical Scan Module aside
and follow Vertical Scan Module –
Installing procedure.
Torx Screws
Rear
Vertical Scan Module
Vertical engine
Stratos Scanner Shown Upside-down, Hood Cover
Removed, Rear View.