32
©2004 Metrologic Instruments, Inc. All rights reserved MS2020 Stratos Service Manual
SERVICING AND MAINTENANCE PROCEDURES
OPENING & ACCESSING INTO STRATOS BOTTOM BUCKET
** Vertical Hood must be removed prior to
opening bottom bucket area.
1. Opening & Accessing Stratos Bottom
Bucket
2. Locate and remove all screws shown in
figures to the right.
3. Remove Stratos Scanner chassis from
counter. (Refer to Removal Instructions
on page 29 of this manual.)
4. Carefully turn Stratos Scanner unit
upside-down and locate the 4 TORX
Screws keeping the Horizontal Scanner
Module in place. (Refer to Figure to the
right.)
5. Using a size T-10 torx screwdriver,
remove all 4 torx screws noted in
previous step.
6. Carefully grip Horizontal Scanner
Module with both hands, one hand on
each side of the Module.
7. With a gentile pulling motion, module
should easily lift out of Stratos chassis.
8. Place old Horizontal Scan Module aside
and follow Vertical Scan Module –
Installing procedure located on page 40
of this manual.
Screws to be removed.
Rear Cover Plate
Screws to be removed.