With X.21 DTE ( CAB-X21-MT ) fitted
Metrodata WCM-Serial "" Alarms: Major
WAN
State Up
interface X.21
mode DTE
'C' control On
'I' state Off
First CAPITAL - select item
<escape> - exit menu
5.3.5.1 State
The state configuration defines the Administrative State of the WAN Serial port. For
normal operation it must be set to UP.
In applications where the WAN link is not used, the state should be set to Down to disable
the alarm processing on the WAN port.
5.3.5.2 Interface
This display item shows the type of cable that is fitted, and the electrical specification of
the serial interface. The following options are supported:
DTE
DCE
V.35
CAB-V35-MT
CAB-V35-FC
X.21
CAB-X21-MT
CAB-X21-FC
EIA-530 CAB-530-MT
V.36
CAB-V36-MT
CAB-V36-FC
No Cable No cable fitted
The serial cables all have identifiers in the HD60 connector to identify them and the multi