CONFIGURING THE ATM CBR DSU
29
76-02-031E
Below the
CLEAR ALARM OUTPUTS
line on the menu screen are the port identities.
Selecting a port leads to the alarm list for that port. The alarms are labelled from 0 to 9 and
A to Z in the firmware. These label numbers are standard for all Metrodata DSUs. Only those
alarms that apply to the particular interface are displayed. Initially they show their default
settings, but they can be selected by their label, and toggled to a different level with choices
MAJOR, MINOR
or
NONE.
Figure 5.6 Port alarm examples
The default settings for alarms are tabulated below for all ATM CBR DSU interfaces.
Figure 5.7 Default alarm settings
E3 PORT
SDH/SONET PORT
0 - LOS
Major
0 - LOS
Major
3 - AIS
Minor
1 - LOF
Major
3 - AIS
Minor
4 - FERF
Minor
A - OOSP
Minor
M - ATM LOC
Minor
HIGHLIGHTED letter - select item
<escape> - exit menu
Port
type
Port
LOS
AIS
LOF
SQ
RAI/
FERF
OOSP
LOC
CBR
E1
Major
Minor
CBR
E2
Major
Minor
CBR
E3
Major
Minor
CBR
DS3
Major
Minor
UNI
E3
Major
Minor
Major
Major
Minor
Minor
UNI
DS3
Major
Minor
Major
Major
Minor
Minor
UNI
TAXI
Major
UNI
SDH/
Sonet
Major
Minor
Major
Minor
Minor
Minor
Summary of Contents for ATM CBR DSU
Page 2: ......
Page 4: ......
Page 10: ......
Page 16: ...INTRODUCTION 76 02 031E 6...
Page 20: ...STATUTORY INFORMATION 76 02 031E 10...
Page 34: ...INSTALLING SETTING UP 76 02 031E 24...
Page 56: ...CONFIGURING THE ATM CBR DSU 76 02 031E 46...
Page 78: ...ANALYSING PERFORMANCE 76 02 031E 68...
Page 88: ...E1 CBR PORT CONFIGURATION 76 02 031E 78...
Page 92: ...E2 CBR PORT CONFIGURATION 76 02 031E 82...
Page 96: ...E3 CBR PORT CONFIGURATION 76 02 031E 86...
Page 100: ...DS3 CBR PORT CONFIGURATION 76 02 031E 90...
Page 106: ...E3 UNI PORT CONFIGURATION 76 02 031E 96...
Page 112: ...DS3 UNI PORT CONFIGURATION 76 02 031E 102...
Page 120: ...SDH Sonet UNI PORT CONFIGURATION 76 02 031E 110...