ANALYSING PERFORMANCE
76-02-031E
54
6 . 4. 3 Summary presentations
The summary screens are designed to give a view of the alarm and error status on a single
screen. There is a choice of update frequencies of the data so that the user can choose the
optimum presentation at any time.
The type of interface being monitored is shown at the top right of the screen. Always check
this when viewing a screen for the first time. Also, if a diagnostic test is being run, its name
appears below the interface type at the top right of the screen entitled
DIAGS
.
The
Temporary counts
column is used to obtain error counts over a user definable test
period, the duration of which need not be time related to anything else, without erasing the
entire statistics database. You can reset the
Temporary counts
by pressing
C
. This means
that a measurement may be started after a 15 minute interval has partly elapsed. The counts
are displayed for the temporary measurement period from its start until you clear it down by
pressing
C
.
Thus, the
Temporary counts
column can be used when first investigating an error condition.
The column can be cleared without losing the historic data, and the user is then given an
instant view of error build-up from the time of clearance onwards.
Pressing any key other than
C
or <Esc> will instantly refresh the display. This applies to each
of the display styles -
Static, Updated
and
15-minute
displays.
The
Current 15-mins
column gives the error counts for the current partial 15 minute period.
Therefore the duration of statistics within this column varies between 0 and 15 minutes in a
cyclical fashion as time passes.
The
Previous 15-mins
column gives the error counts for the previous complete 15 minute
period, assuming that there has been one.
The
Last 24 hours
column gives the error counts for the previous 24 hour period, as an
accumulation of the last 96 complete
Previous 15-mins
periods.
The three
DISPLAY MODES
for summaries are defined below. They dictate the frequency
with which the display data is updated. The format of the displays is the same for any one
interface regardless of the mode.
Static summary
This option presents the data as a single screen display, giving a snapshot of the current
status. The information in the display may be updated by pressing any key except <escape>.
Updated summary
This is similar to a static summary except that the screen is refreshed approximately every
5 seconds, and provides a dynamic display of events.
15 minute summaries
This updates the information in a summary at the end of each 15-minute period. This mode
is useful where a printer is connected to the terminal port and a detailed log is required.Once
one of these summary modes has been selected for display, three
STYLES
of display are
available for selection, as described below.
Summary of Contents for ATM CBR DSU
Page 2: ......
Page 4: ......
Page 10: ......
Page 16: ...INTRODUCTION 76 02 031E 6...
Page 20: ...STATUTORY INFORMATION 76 02 031E 10...
Page 34: ...INSTALLING SETTING UP 76 02 031E 24...
Page 56: ...CONFIGURING THE ATM CBR DSU 76 02 031E 46...
Page 78: ...ANALYSING PERFORMANCE 76 02 031E 68...
Page 88: ...E1 CBR PORT CONFIGURATION 76 02 031E 78...
Page 92: ...E2 CBR PORT CONFIGURATION 76 02 031E 82...
Page 96: ...E3 CBR PORT CONFIGURATION 76 02 031E 86...
Page 100: ...DS3 CBR PORT CONFIGURATION 76 02 031E 90...
Page 106: ...E3 UNI PORT CONFIGURATION 76 02 031E 96...
Page 112: ...DS3 UNI PORT CONFIGURATION 76 02 031E 102...
Page 120: ...SDH Sonet UNI PORT CONFIGURATION 76 02 031E 110...