Multi LAN 350
Operation
35
PSELFEXT worst case result screen
Note:
The PSELFEXT measurement can't be performed without the remote unit.
PSELFEXT PLOT screen
After entering this screen individual or all PSELFEXT (frequency) plots together with the
test standard limit curve are shown on the display. Margin and result at the cursor
position are displayed under the graph.
The following actions can now be performed:
ESC key:
return to PSELFEXT result screen
NEXT PAIR:
view next plot
Left, Right key:
move cursor left and right to view margin
and result at selected frequency.
Up, Down key:
move cursor up and down along the
amplitude axis.
PSELFEXT plot screen
5.3.6 RETURN LOSS, Remote RETURN LOSS
Return loss is the ratio between transmitted and reflected signals at the transmission
end. High return loss rates are often caused by local impedance mismatching and
decrease the signal strength on the receiver end.
The main result is given in dB as the worst case margin to the test standard limit.