Multi LAN 350
Operation
21
5 Multi LAN 350 Operation
5.1 Test connections
5.1.1 Permanent link connection
Permanent Link connection is used when the fixed installed section of cabling is tested.
On figure below, the network connection for a permanent link test can be seen. It
consists of:
- one connection at the patch panel
- a horizontal cable segment (up to 90m long)
- a consolidation point (optional)
- connection at the telecommunications outlet.
The important feature is that in the Permanent link the test equipment cables don’t
influence the result.
Main unit
Remote
(2)
(1)
(3)
(4)
(5)
(1) Equipment patch cord
(2) Telecommunication outlet
(3) Consolidation point
(4) Horizontal cable
(5) Horizontal cross connect
WORK AREA
FLOOR DISTRIBUTION
H
O
R
IZ
O
N
T
A
L
C
A
B
L
IN
G
.......
.......
.......
.......
Maximal test connection for a Permanent Link