Multi LAN 350
Specifications
18
3.4.10 PSELFEXT
Frequency Range
Resolution Accuracy
1 MHz – 350 MHz
0.15 MHz
better than calculated accuracy model
(TIA/EIA 568-B.2)
Perm. Link Channel
< ±2.1 dB ±3.6 dB at 100 MHz
< ±3.7 dB ±4.8 dB at 250 MHz
Measuring Range
0.0 – 70.0 dB
0.1 dB
defined up to 3 dB over category 6 limit,
62 dB max
3.4.11 Return Loss, Remote Return Loss
Frequency Range
Resolution Accuracy
1 MHz – 350 MHz
0.15 MHz
better than calculated accuracy model
(TIA/EIA 568-B.2)
Perm. Link Channel
< ±3.5 dB ±2.8 dB at 100 MHz
< ±4.2 dB ±4.8 dB at 250 MHz
Measuring Range
0.0 – 40.0 dB
0.1 dB
3 dB over test limit, 23 dB max
3.4.12 ACR, Remote ACR
ACR is computed from NEXT and Attenuation results.
ACR (f) = NEXT (f) - Attenuation (f)
The accuracy is calculated from the NEXT and Attenuation accuracies.
3.4.13 PSACR, Remote PSACR
PSACR is computed from PSNEXT and Attenuation results.
PSACR (f) = PSNEXT (f) - Attenuation (f)
The accuracy is calculated from the NEXT and Attenuation accuracies.
3.4.14 TDR (Time Domain Reflectometer)
Distance Range/ Pulse
length
Resolution
(ns, m at NVP=0.69 c)
Distance Accuracy
0-10 (50, 100) m
0-200 m
0-400 m
1 ns, 0.1 m
2 ns, 0.2 m
4 ns, 0.4 m
±(3 % + 5 dig)
±(5 %)
±(5 %)
Amplitude Range
Resolution
Accuracy
in percents
1 %
not defined
Selectable propagation velocity rate
0.50c – 0.99c
Gain
autogain, 6 stages