![METREL EurotestXC Instruction Manual Download Page 76](http://html1.mh-extra.com/html/metrel/eurotestxc/eurotestxc_instruction-manual_1779026076.webp)
MI 3152(H)
Eurotest
XC (2,5 kV)
Tests and measurements
76
7 Tests and measurements
See chapter
6.1 Selection modes
for instructions on keys and touch screen functionality.
7.1
Voltage, frequency and phase sequence
Figure 7.1: Voltage measurement menu
Measurement parameters / limits
There are no parameters / limits to be set.
Connection diagrams
Figure 7.2: Connection of 3-wire test lead and optional adapter in three-phase system
Figure 7.3: Connection of Plug commander and 3-wire test lead in single-phase system
Measurement procedure
Enter the
Voltage
function.
Connect test cable to the instrument.
Connect test leads to object under test (see
Figure 7.2
and
Figure 7.3
).