7. Error code table
Code
Error
Cause
Action by user
01
Hardware over coil
Unsuitable pan material
Wrong or defective coil
Use suitable pan Call
Service Engineer.
02
No inductor current
IInductor connection
failure
Call Service Engineer.
03
Heat sink temperature
too high
Air routes blocked. Fan
filter clogged. Genera-
tor temperature sensor
defective
Clear air routes.
Clean fan air intake filter. If still faulty,
call Service Engineer.
04
Cooking zone tempera-
ture too high or too low
Pan empty
Pan base distorted
Coil temperature sensor
faulty
Remove pan, check pan base. Switch
off, allow zone to cool and try again. If
still faulty, call Service Engineer.
05
Control unit failure
Control / switch assem-
bly is faulty or wired
incorrectly
Call Service Engineer.
06
Internal temperature too
higha
Air routes blocked. Fan
filter clogged. Tem-
perature sensor faulty,
external heat sources
too close
Clear air routes. Clean fan filter. Remove
any external heat source.
If still faulty, call Service Engineer.
07
Cooking zone tempera-
ture sensor
Short circuit at tempera-
ture sensor
Call Service Engineer.
08
Mains phase failure
Fault in mains supply
Call Service Engineer.
10
Communication error
Failure in LIN or CAN-
Bus No connection
between keyboard and
generator
Disconnect from mains. Reconnect and
test again.
Call Service Engineer.
11
Initialisation error
Failure while initialising
hardware
Wait. Generator will reset every 30 sec-
onds. Try switching off and on.
12
Mains current failure
Failure while generator
measures mains current
Call Service Engineer.
13
Mains connection error
Mains voltage too high
or too low
Call Service Engineer.
14
Mains adaptor error
Mains voltage too high
or too low
Call Service Engineer.
15