M ET E K
M ic r o R a i n R a d a r M R R - 2
19
10.2010 Valid for MRR Service Version ≥ 5.2.0.9
Figure 9: Login Screen
If you are sitting at the PC which is directly connected to the MRR-2 leave the
entry at
Name of the Remote PC
empty (or type a period or the name of the
local PC). If you are sitting at another PC, enter the name of that PC to which
the MRR-2 is connected directly and where the communication service
(
MrrCtrl.exe)
was started.
The User Name is generated automatically and the Password is usually not
needed (see below for exceptions).
The
Password
entry field is useful if the remote computer is a member of an-
other Windows domain, because in this case a connection can be built up only
if a user name and the matching password is given. The user name is set au-
tomatically (see the header of the dialog window).
The network connection to the remote computer usually is a LAN- or a RAS
connection. RAS connections using the public telephone net are mostly not
very efficient, especially connections with mobile phone radio nets. Con-
sidering that, the login dialog provides the use of time-out-values which are
adjusted to the maximum delay times for the responses from the remote PC.
Using a direct LAN or a local login, this feature is not needed.
If the program was started by a command line input, the information concern-
ing the login window can be handed over as a parameter. Example:
C:\METEK\MrrCtrl hostname secret /t
This entry would try to build a connection to a computer with the name
\\hostname
. The password is
secret
, the time-out-values are set for slow
WAN connections (
/t
). The parameter
/t
is optional, the computer name and
the password however must be given always. This is also valid for local logins
(the password will not be checked).