System Part Numbers
Part Number
Item Description
BGA-3591
BGA rework system with high power under-board heater, split field vision system &
monitor 115V NTSC
BGA-3592
BGA rework system with high power under-board heater, split field vision system &
monitor 230V PAL
CSP-3501
CSP Rework System, 115V. NTSC with monitor
BGA-3591-G
BGA Rework System, 115V. NTSC w/o monitor
CSP-3501
CSP rework system with under-board heater, high magnification vision system &
monitor 115V NTSC
CSP-3502
CSP rework system with under-board heater, high magnification vision system &
monitor 230V PAL (Contact Metcal for NTSC format)
CSP-3501-G
CSP Rework System, 115V. NTSC w/o monitor
BGA-3592-G
BGA Rework System, 230V. PAL w/o monitor
CSP-3502-G
CSP Rework System, 230V. PAL w/o monitor
BGA-3591J
BGA rework system with high power under-board heater, split field vision system &
monitor 100V - Japan only NTSC
BGA-3591J-SN
BGA rework system with high power under-board heater100v - Japan only
CSP-3501J-G
CSP Rework System, 100V. NTSC w/o monitor
BGA-3592-N-G
BGA Rework System, 230V. NTSC w/o monitor
CSP-3502-N-G
CSP Rework System, 230V. NTSC w/o monitor
Please note: Monitor will be supplied locally and specification will vary.
Environmental Conditions (all models)
• Suitable for indoor use only at altitudes not exceeding 6500 ft (2km)
• All systems must be grounded
• Maximum relative humidity of 80% at 88°F (31°C) decreasing linearly to 50% at 104°F (40°C)
• Temperature range of 41°F (5°C) to 104°F (40°C)
• Mains supply voltage fluctuations not to exceed ±10% of the nominal voltage
• Pollution degree 2 per IEC 644
• Insulation category II
Vision Systems
The BGA-3500 systems provide a maximum four-sided view of 46mm x 46mm (1.77” x 1.77”) with a diag-
onal overlay on the component corners for improved alignment. The zoom lens magnification has a range of
10X to 50X.
3
BGA-3500 Series Manual 5/01