8.3 Alarm Settings
8.3.1 Alarm Input Settings
In the Alarm-Settings sub menu, user can define the alarm behaviors and the corresponding actions for triggered alarm.
Alarm input – Select the alarm input number from 1 to 8, the corresponding settings will show in the window.
●
Enabled
Select On to enable the alarm.
●
Alarm name
Input the name for the alarm.
●
Alarm type
Select the alarm trigger type.
N.O. – Normal open contact, N.C – Normal Close contact
●
Trigger Duration
Select the trigger type and time duration
Timeout – The alarm will last for the set time duration.
Transparent – The alarm output remains active until the triggered event ends.
Non-Stop – The alarm will be continuously active until user presses “ACK” key.
●
Alarm Handle
To configure the system monitor and alert behavior when the alarm is triggered. The settings include buzzer, spot option,
trigger alarm out, send Email.
●
Triggered Camera
The system allows user to trigger multiple cameras for event recording, select the cameras that would like to be triggered
when alarm is detected.
Click
Apply
to save the settings.