6
When you open the housing cover for installation, you will find behind it an additional product information label on the lower
part of the electronic components cover, which will also carry the ABL model number.
Using the Mercedes-Benz product identification number or the ABL model
number, please always ensure before installation that your wallbox model
variant is the one whose installation is described in this document. You can
find a list of the wallbox model variants described in this manual and the
correlations between Mercedes-Benz product identification numbers and
ABL product numbers in the table below.
The following wallbox model variant is the subject of this manual:
Mercedes-Benz product
identification number
ABL model number
Grid connection
Model Variant
A0009060307
3W72M2
see product label
Fixed charging cable according to IEC 62196-2 Type 1, ca. 7.4 m;
charging output 7.2 kW
CAUTION!
The information and technical specifications contained in this manual relate exclusively to the model variant mentioned
in this manual and must not be transferred to other wallbox models. These variants include specific instruction manuals
where
necessary.
Should your wallbox model variant not be described in this manual, please contact your local Mercedes-Benz technical
support: Do not under any circumstances install the wallbox in this case, as this could lead to damage to the wallbox, to
injury and/or death.
General requirements of the installation site
Your Mercedes-Benz Wallbox is an electrical device and is therefore subject to particular requirements for indoor and outdoor
installation. In selecting the installation site, you must consider the following points:
•
Consider all local regulations for electrical installations, fire protection and accident prevention.
•
The wallbox must be installed where it is freely accessible to all authorized users.
•
A parking spot must also be planned for in front of the wallbox so that the vehicle can at all times
be reached with the integrated or with an external charging cable.
•
The recommended installation height is 120 to 140 cm from the floor to the lower edge of the
housing. This recommendation may be adjusted upwards or downwards depending on local
conditions. Sufficient air circulation must be ensured at the installation site so that the wallbox
is cooled during operation: Always observe the allowed operating temperatures (see “Technical
specifications” on page 21).
•
The mounting area must have an even surface that provides sufficient stability for installing the
wallbox.
•
The required mounting area for the Mercedes-Benz Wallbox is at least 512 x 429 mm (H x W). All
of the mounting plate of the wallbox must be in contact with the mounting surface.
•
To ensure the safe operation of the wallbox, minimum clearances of 50 cm must be kept on all
sides of the housing.
•
In general, the Mercedes-Benz Wallbox is engineered for operation in high ambient temperatures.
However, it must be ensured that the maximum operating temperature is not exceeded through
external influences such as direct sunlight or similar.
3W72M200001
120 to
140 cm