10
10. Hang the wallbox onto the mounting plate by inserting the screw in the
center of the upper part at the rear into the respective opening in the
mounting plate: this already protects the wallbox from falling.
11. Now fix the wallbox to the mounting plate using the screwdriver (TX25 bit)
and the four 6 x 25 screws included. The wallbox is now securely fastened
to the mounting plate.
12. If using a power supply with flexible wires, ensure that the stripped ends
are fitted with wire end ferrules. Loosen the lower screws in the terminal
blocks, insert the wires into their respective terminal and tighten with
a torque of 2.5 to 3 Nm. The wiring sequence is shown in the following
diagram and table.
The supply cable for the single phase model variant A0009060307 is connected as follows:
Designation
Wire colors
Connection coding
Current-carrying conductor phase 1
Brown
L1
Neutral
Blue
N
Protective earth
Green-Yellow
PE
PE L1 L1 N N PE