MAINTENANCE
45V4 • 55V4 • 60V4 ENG
3-2
MAINTENANCE INTERVALS
Periodic maintenance is most important to operate the machine safely and demonstrate its
performances fully.
Take special care when using the machine under severe condition.
ǻ
: Check.
{
: Replace.
Maintenance
point
Maintenance
work
Maintenance interval
Daily
50h
100h
250h
500h 1000h 1500h 2000h
Irregular
G
re
a
s
in
g
Attachment
Grease
ǻ
Boom swing
ǻ
Blade
ǻ
Swing bearing
ǻ
Ring gear
ǻ
B
u
c
k
e
t
Bucket tooth
Check wear
ǻ
{
Bucket
Check
damage
ǻ
{
Clearance
Adjust
ǻ
C
ra
w
le
r
Rubber track
Check wear &
deterioration
ǻ
{
Track tension
Check and
adjust
ǻ
R
e
d
u
c
ti
o
n
g
e
a
r
Travel reduction
gear
Check oil leak
ǻ
Check oil qty &
refill
ǻ
Change oil
{
First
time
{
Summary of Contents for Menzi IHI 45v4
Page 2: ...45V4 55V4 60V4 WG010001 WY010001 WZ010001 45V4 55V4 60V4 0988405EN...
Page 6: ...45V4 55V4 60V4 ENG...
Page 10: ...FOREWORD 45V4 55V4 60V4 ENG 4 This page is intentionally left blank...
Page 12: ...45V4 55V4 60V4 ENG...
Page 25: ...SAFETY 45V4 55V4 60V4 ENG 1 13 This page is intentionally left blank...
Page 32: ...45V4 55V4 60V4 ENG...
Page 84: ...OPERATION 45V4 55V4 60V4 ENG 2 52 This page is intentionally left blank...
Page 86: ...45V4 55V4 60V4 ENG...
Page 127: ...MAINTENANCE 45V4 55V4 60V4 ENG 3 41 This page is intentionally left blank...
Page 131: ...45V4 55V4 60V4 ENG SPECIFICATIONS...
Page 132: ...45V4 55V4 60V4 ENG...
Page 144: ...SPECIFICATIONS 45V4 55V4 60V4 ENG 4 12 RATED OBJECT HANDLING CAPACITIES TABLE 45V4...
Page 145: ...SPECIFICATIONS 45V4 55V4 60V4 ENG 4 13 55V4...