85-03-00944
9 |
P a g e
TECHNICAL SPECIFICATIONS
MODEL FV41-ARCH
High Fire - Adjustable to - Low Fire
BTUH. (MODEL FV-41-ARCH)
NAT. GAS
40,000
11,622
BTUH. (MODEL FV-41-ARCH)
LP GAS
40,000
15,152
NOTE: LPG CONVERSION KIT, HA-92-00014, MUST BE PURCHASED
SEPARATELY TO CONVERT TO BURN LPG IN THIS FIREPLACE.
MAIN ORIFICE [0-2000ft (610 m)]: REAR BURNER: #42 NG [#54 L.P.] – FRONT BURNER: #42 NG [#54 LP]
........................ [2000-4500ft (610-1370 m)]: REAR BURNER: #43 NG [#55 L.P.] – FRONT BURNER: #42 NG [#54 LP]
OVERALL EFFICIENCY: ..................... ..AFUE NG 71.2%, AFUE LP 74.4%, P.4 FE 77.18%
CO-AXIAL DIRECT VENT FLUE: .......... 5" INNER, 8" OUTER
TOTAL WEIGHT: ................................... 235 POUNDS
SAFETY: ................................................ AGA/CECERTIFIED IPI AUTO ELECTRONIC IGNITION SYSTEM
ACTIVATED WITH THERMOSTATIC REMOTE CONTROL.
APPLIANCE CERTIFICATION AND TESTING AGENCY
INTERTEK TESTING SERVICES, ICBO#AA647-4
Certified under ANSI Z21.88 (2014)
CSA 2-33 (2014) “Vented Gas Fireplace Heaters" not for use with solid fuel. Approved for bed-
room installations and mobile homes. UL307B approved for "mobile homes, after first sale of home, not for recreational vehicles."
GAS REQUIREMENTS
.......................... SUPPLY PRESSURE:
GAS INLET: 1/2" N.P.T.
NAT.
GAS:
7" W.C.
(5" W.C. MIN., 11" W.C. MAX.)
L.P.
GAS:
11.0" W.C.
(11" W.C. MIN., 13" W.C. MAX.)
ELECTRICAL REQUIREMENTS
........... 115 VOLT, LESS THAN 1.5 amps (for blower operation only)
APPROVED VENT SYSTEMS
............... DURAVENT, SELKIRK, AMERIVENT, SECURITY
MINIMUM CLEARANCES TO COMBUSTIBLE CONSTRUCTION
UNIT TO FLOOR
0in. (0mm)
INNER GUIDE EDGE TO ADJACENT SIDEWALL
16in. (406 mm)
UNIT TO ENCLOSURE SIDEWALL
1/2in. (13mm)
VENT PIPE TOP TO COMBUSTIBLES
2in. (51mm)
UNIT TO ENCLOSURE BACK WALL
1/2in. (13mm)
VENT PIPE SIDES TO COMBUSTIBLES
1in. (25mm)
UNIT BOTTOM TO ENCLOSURE CEILING 53-1/2 in. (136 cm)
VENT PIPE BOTTOM TO COMBUSTIBLES 1in. (25mm)
UNIT BOTTOM TO ROOM CEILING
72 in. (1829 mm)
8” MANTLE ABOVE DISCHARGE AIR OPENING
18 in. (457 mm)
MINIMUM COMBUSTIBLE ROUGH FRAMING DIMENSIONS
WIDTH = 45” (114.3cm)
HEIGHT = 50-1/2” (128cm)
DEPTH = 19-3/16” (49cm)
THIS FIREPLACE INCLUDES A SEALED COMBUSTION SYSTEM, 8-PIECE CERAMIC FIBER LOG SET & COALS, FIREBRICK
LINED FIREBOX, NEO-CERAM GLASS, ELECTRONIC IGNITION SYSTEM, DUAL BLOWERS, AGA CERTIFIED SAFETY SYSTEM,
ACCENT LIGHT and THERMOSTATIC REMOTE CONTROL.
FRONT OPTIONS: GRACE, WILLOWBROOK, BENTLEY DOORS, TRADITIONS - BLACK, VINTAGE IRON, SWEDISH NICKEL,
ANTIQUE COPPER.
CAUTION
THESE INSTRUCTIONS ARE TO
REMAIN WITH THE HOMEOWNER.
NOTE:
This installation must conform to local codes. In the absence
of local codes, you must comply with the
National Fuel Gas Code,
ANSI Z223.1-latest edition
in the U.S.A. and the Natural Gas and
Propane Installation Code,
CSA B149 Installation Codes
in Cana-
da.
This appliance may be installed in an
aftermarket, permanently located,
manufactured home (USA only) or
mobile home, where not prohibited
by local codes.
This appliance is only for use with
the type(s) of gas indicated on the
rating plate.
WARNING:
Do not operate this appliance with the glass removed,
cracked or broken. A licensed or qualified person should do re-
placement of glass.
HIGH ALTITUDE INSTALLATION INFORMATION
: Prior to installing at altitudes higher than 7500, please con-
tact the Mendota technical service department for specific venting requirements and venting restrictions.
Summary of Contents for FV41-ARCH
Page 32: ...85 03 00944 32 P a g e 45 1 2 42 1 2 46...
Page 34: ...85 03 00944 34 P a g e...
Page 36: ...85 03 00944 36 P a g e FEET MAXIMUM...
Page 59: ...85 03 00944 59 P a g e...
Page 60: ...85 03 00944 60 P a g e...
Page 61: ...85 03 00944 61 P a g e...
Page 62: ...85 03 00944 62 P a g e...
Page 63: ...85 03 00944 63 P a g e...
Page 64: ...85 03 00944 64 P a g e...
Page 65: ...85 03 00944 65 P a g e...