MANTEL CLEARANCES
Mantel Clearances for this fireplace may be measured from
the top of the convection air opening
or
the floor level of
this fireplace
.
The location that is referenced normally to measure mantel clearances is the Top of the Convection Air Opening. For
ease, however, measure up from the floor level of this fireplace. The chart and diagram, in this page, provide all the refer-
ence dimensional information necessary in determining the distance a combustible mantel may protrude out from the face
surface of this fireplace. The Chart, at right, shows the Distance from Fireplace Face the combustible mantel may pro-
trude outward at a Distance up From Floor Level of this Fireplace.
If you prefer to take measurements from the Top of the Convection Air Opening, note that the Top of the convection air
opening is 30 inches up from the floor level of this fireplace.
WARNING:
Make proper use of this chart. Do not compromise the specifications contained in this chart.
Failure to adhere to proper clearances required to combustibles may cause spontaneous combustion of the mantel and
may result in a fire causing property damage, personal injury or loss of life.
NON-COMBUSTIBLE ZONE
F
IR
E
PLA
C
E
F
A
C
E
M
U
S
T
BE CO
VERED W/
NO
N
C
O
M
B
U
S
T
IBLE
FA
CING
I
N
TH
IS
A
R
EA.
A
C
O
MBUS
TI
BL
E MA
NTEL
I
S
N
O
T
A
L
L
O
W
E
D
I
N
TH
IS
AREA.
Summary of Contents for FV41-ARCH
Page 32: ...85 03 00944 32 P a g e 45 1 2 42 1 2 46...
Page 34: ...85 03 00944 34 P a g e...
Page 36: ...85 03 00944 36 P a g e FEET MAXIMUM...
Page 59: ...85 03 00944 59 P a g e...
Page 60: ...85 03 00944 60 P a g e...
Page 61: ...85 03 00944 61 P a g e...
Page 62: ...85 03 00944 62 P a g e...
Page 63: ...85 03 00944 63 P a g e...
Page 64: ...85 03 00944 64 P a g e...
Page 65: ...85 03 00944 65 P a g e...