85-03-00944
10 |
P a g e
GENERAL INSTALLATION INFORMATION
Your Mendota Gas Fireplace has a state-of-the-art co-axial direct vent, sealed combustion system. This advanced and highly
efficient system brings in outside air for combustion, has a separate exhaust vent and efficiently heats and re-circulates room air.
The Mendota system maintains high air quality, maximizes efficiency and assures proper operation in today's "air-tight" homes.
SAFETY AND STRUCTURAL CONCERNS:
The FV41-ARCH Fireplace must be installed and serviced by a Mendota approved serviceperson. Any adjustments to burner,
pilot, logs or coal bed must be made by a Mendota approved service person. If pilot goes out, always wait five (5) minutes be-
fore attempting to relight pilot.
VENTING REQUIREMENTS:
This Mendota Fireplace can be vented using many available LISTED DIRECT VENT coaxial pipe (5”X 8”) off the top.
Approved
brands of vent components include DuraVent, Amerivent, ICC, Selkirk and Security vent pipes and venting components.
However, Sconce Shaped Caps are prohibited due to exhaust recirculation concerns. Closely follow venting locations, directions
and requirements. Observe the restrictions relating to vent position on exterior of home. Be sure all vent pipe sections are fully
twist-locked and leak-proof. Be sure 1000
º
Silicate Stove Sealant is used on the inner pipe joints of all Simpson DuraVent pipe
components and all adjustable pipe sections.
The Mendota Direct Vent Fireplace may be placed within 18 inches of adjacent sidewalls. The fireplace may be placed directly
on concrete or wood flooring. If the appliance is to be installed on carpeting, vinyl or other combustible material other than wood
flooring, the appliance shall be installed on a metal or wood panel extending the full width and depth of the appliance. An 8”
combustible mantel may be installed at a minimum of 18" above top of the heat outlet (51.5”) up from the floor level of this fire-
place) and no more than 8" out from wall at that height. Non-combustible (marble, brick, stone, etc.) mantels can be installed at
any desired height above the top convection air opening. Combustible Mantels of any depth with a sheet metal protector plate in
its under-side may only be installed
outside
the “NON-COMBUSTILBE ZONE” above the top convection air opening.
Never block off convection air openings or paths. Always use Mendota decorative fronts and Mendota approved vent systems
and vent caps.
A non-combustible hearth protector with a total insulation rating of R-1 is required when installing this fireplace directly on the
floor and must extend a minimum of 18" in front of the fireplace. For every 1 inch the fireplace is raised off the floor, the depth of
the hearth protector may be reduced by 2 inches. If fireplace is raised off the floor 6" or more, no hearth protector is required.
HEATING PERFORMANCE:
With its high heat output this Mendota Fireplace will heat a large area of your home if located properly to maximize heat/ air cir-
culation. Air movement options for maximizing heat circulation that can be considered are the continuous operation of central
heating furnace blowers or ceiling fans.
The most efficient method for overall heat distribution within a single room is a
ceiling fan.
The heat output of the Fireplace can be reduced to a low 13,000 BTUH by turning off the Rear Burner and reducing
flame height using the remote control. Blower can be turned down or turned off to reduce heat output.
AESTHETIC CONSIDERATIONS:
Burning or static fireplaces are a major aesthetic focus in any room. Locate your gas fireplace as you would a television set.
The Mendota Hearth Gas Fireplace will be a continuing source of comfort and fascination. Corner installations will afford you
the greatest potential for viewing in many rooms. We suggest installing this Mendota Fireplace a minimum of 12 inches above
the floor by utilizing an elevated hearth. This fireplace may be installed in an elevated position as long as 72 in. minimum dis-
tance is provided between the floor level of this fireplace and the room’s ceiling surface.
ELECTRICAL REQUIREMENTS:
Electronic Ignition System, Dual Blowers and an Accent Light system are included in this Mendota Direct Vent Fireplace. These
devices require constant electrical power except during power outages. A 115-volt electrical service must be supplied at the
fireplace location at the time of installation, on the left side of this fireplace. It must be electrically grounded in accordance with
local codes, or in their absence, with the current edition of the National Electric Code ANSI/NFPA 70. Use of a wall switch con-
trol in the power supplied to this fireplace is NOT allowed.
Three loose wires are secured to a metal junction box on the left side of the fireplace. Use the supplied wire nuts to con-
nect house power to the three color-coded loose wires.
Thermostatic function is included in the Remote Control Transmitter. Therefore, no Thermostat wire is required.
Summary of Contents for FV41-ARCH
Page 32: ...85 03 00944 32 P a g e 45 1 2 42 1 2 46...
Page 34: ...85 03 00944 34 P a g e...
Page 36: ...85 03 00944 36 P a g e FEET MAXIMUM...
Page 59: ...85 03 00944 59 P a g e...
Page 60: ...85 03 00944 60 P a g e...
Page 61: ...85 03 00944 61 P a g e...
Page 62: ...85 03 00944 62 P a g e...
Page 63: ...85 03 00944 63 P a g e...
Page 64: ...85 03 00944 64 P a g e...
Page 65: ...85 03 00944 65 P a g e...