Code Parameter
Min. Max. Incre-
ment
De-
fault
Unit
Comment
101
(4)
External switch
mode
0
3
1
1
0 = deactivated
1 = air flow
2 = mode
3 = not used
131
This code only applies for ventilation units from the M-WRG-II series
123
This code only applies for ventilation units from the M-WRG-II series
96
(5)
InControl push-
button sensor
standby ON/OFF
0
1
1
1
0 = standby OFF
1 = standby ON
133
This code only applies for ventilation units from the M-WRG-II series
134
This code only applies for ventilation units from the M-WRG-II series
151
This code only applies for ventilation units from the M-WRG-II series
152
This code only applies for ventilation units from the M-WRG-II series
153
This code only applies for ventilation units from the M-WRG-II series
154
This code only applies for ventilation units from the M-WRG-II series
168
This code only applies for ventilation units from the M-WRG-II series
169
This code only applies for ventilation units from the M-WRG-II series
170
This code only applies for ventilation units from the M-WRG-II series
93
Restore factory
default settings
0
1
1
0
1 = restore factory default
settings
Table 8: Variable parameters in the Device settings menu for ventilation units from the M-WRG series
(1) See list of modes in section 9.4.5 on page 40
(2) Hold down the
or
button to scroll through the values faster
(3) For the M-WRG-S/Z-T-FC and M-WRG-S/Z-KNX-FC unit types, the wireless remote control can be used to assign
the “CO
2
” program button on the InControl pushbutton sensor to the “Automatic mode” ventilation program. In this
case, the ventilation mode will be regulated in relation to the mixed gas/CO
2
concentration
and
the relative room air
humidity.
(4) Code 101 is used to set up buttons 1 to 3 on the 4-way wireless pushbutton switch M-WRG-FT and for the wireless
sensors:
Value 1: button 1, 2, 3 = LOW, MEDIUM, HIGH
(5) Only needed for the InControl pushbutton sensor
9.4.5 List of modes for ventilation units from the M-WRG-II and M-WRG series
Mode
M-WRG-II
M-WRG
0
LOW
LOW
1
MEDIUM
MEDIUM
2
HIGH
HIGH
3
Humidity control
Humidity control
4
CO
2
control
Mixed gas/CO
2
control
5
Automatic mode
Automatic mode