User guide
Wireless remote control M-WRG-FBH
- 38 -
Meltem Wärmerückgewinnung GmbH & Co. KG
Am Hartholz 4 · D-82239 Alling
[email protected] · www.meltem.com
VENTILATION THE RIGHT WAY
V E N T I L A T I O N & H E A T R E C O V E R Y
Code Parameter
Min. Max. Incre-
ment
De-
fault
Unit
Comment
55
Switch-on delay
for external control
input
0
240
1
1
min
56
Follow-up time for
external control
input
0
240
1
15
min
54
Air flow for extract
air/supply air with
external control
input
0
100
10
70
m
3
/h
95
(1)
External control
input mode
0
18
1
12
Selected ventilation
program for external control
input
36
Threshold for
humidity control
40
80
1
60
%
Threshold for humidity
control above which the
ventilation unit increases the
ventilation level
37
Min. air flow for
humidity control
0
100
10
10
m
3
/h
0: control for Standby mode
active
38
Max. air flow for
humidity control
0
100
10
60
m
3
/h
39
Threshold for
mixed gas/CO
2
control
400 1400 1
(2)
600
ppm
Threshold for mixed gas/
CO
2
control above which the
ventilation unit increases the
ventilation level
40
Min. air flow for
mixed gas/CO
2
control
0
100
10
10
m
3
/h
0: control for Standby mode
active
41
Max. air flow for
mixed gas/CO
2
control
0
100
10
60
m
3
/h
16
(1)
Mode for 3-way
stepping switch on
ventilation unit in
position I
0
18
1
0
LOW = reduced ventilation
17
(1)
Mode for 3-way
stepping switch on
ventilation unit in
position II
0
18
1
1
MEDIUM = normal ventila-
tion
18
(1)
Mode for 3-way
stepping switch on
ventilation unit in
position III
0
18
1
2
HIGH = increased ventila-
tion