9.3.3 Overview of the variable parameters in the active ventilation program
Configuration menu*
Ventilation program Variable parameters
Description
Supply air operation
— Ventilation level for
supply air
— Ventilation level for
extract air
The first parameter
flashes. The two
parameters can be set
individually.
Extract air operation
— Ventilation level for
supply air
— Ventilation level for
extract air
The first parameter
flashes. The two
parameters can be set
individually.
Humidity control
— Min. ventilation level
— Max. ventilation level
— Threshold for
humidity
The first parameter
flashes. All the param
-
eters can be set indi-
vidually.
Mixed gas/CO
2
control
— Min. ventilation level
— Max. ventilation level
— Threshold for mixed
gas/CO
2
The first parameter
flashes. All the param
-
eters can be set indi-
vidually.
Automatic mode
— Min. ventilation level
for humidity control
— Max. ventilation level
for humidity control
— Threshold for
humidity
— Min. ventilation level
for mixed gas/CO
2
— Max. ventilation level
for mixed gas/CO
2
— Threshold for mixed
gas/CO
2
The first parameter
flashes. All the param
-
eters can be set indi-
vidually.
Continuous
operation
— Ventilation level for
supply air
— Ventilation level for
extract air
The parameters flash
at the same time and
are set at the same
time.
Intensive ventilation
— Ventilation level for
supply air
— Ventilation level for
extract air
The parameters flash
at the same time and
are set at the same
time.
Table 6: Overview of the variable parameters in the active ventilation program
* For ventilation units from the
M-WRG-II
series, ventilation levels with values between
10 and 99
are displayed.
For ventilation units from the
M-WRG
series, ventilation levels with values between
1 and 10
are displayed.