Installation manual
M-WRG-II M-U
2
- 15 -
Meltem Wärmerückgewinnung GmbH & Co. KG
Am Hartholz 4 · D-82239 Alling
[email protected] · www.meltem.com
VENTILATION THE RIGHT WAY
V E N T I L A T I O N & H E A T R E C O V E R Y
3.7.1 Planning example for installing the installation kit in a frame construction
with a framing member thickness of 160 mm
Fig. 6: Planning example for installing the installation kit in a frame construction with a framing member thickness of
160 mm
A- A
B- B
C
D
A
A
B
B
C
D
1
2
9
3
4
5
6
7
10
8
8
8
10
11
12
4
10
0
16
0
15
15
12
,5
15
31
7,
5
56
102
58
100
118
60
7
6
10
Cutouts in the
upper batten for flat
ductwork
Cutouts in the
lower batten for flat
ductwork
Option:
M-WRG-II M/Fü
filler piece
Note the excess pipe length
specified in the installation man
-
ual for the outer wall terminals.
M-WRG-II ES: 5-10 mm
The OSB board (item 6)
and plasterboard (item 7)
extend over the installa-
tion kit (item 10). In this
version no cutouts are
needed in the OSB board
for the flat ductwork.
289 M-WRG-II M-U
2
(shortened)
Detail of version 1
List of components
Item
Description
1
15 mm external render
2
Wood fibre insulation
3
15 mm OSB board
4
160 x 60 mm framing member
5
160 mm insulation
6
15 mm OSB board
7
12.5 mm plasterboard
8
Batten (support and fixing for installation kit)
9
Outdoor air and exhaust air pipe DN 100
10
Installation kit M-WRG-II M-U
2
(option: M-WRG-II M/Fü filler piece)
11
M-WRG-FK-V flat ductwork connector 110 x 54 mm
12
M-WRG-FK-F flat ductwork 110 x 54 mm