9.2
Sawing channels for flat ductwork or flexible pipes (only when connecting a
flat ductwork or flexible pipe system)
NOTICE
In combination with the optional
ductwork connection adapter
M-WRG-II AD-UP this installation kit
allows you to connect a 110 x 54 mm
flat ductwork system or a 75 or 63 mm
flexible pipe system on the extract air
side (item 1 in Fig. 11), on the supply
air side (item 2 in Fig. 11) or on both
sides. The installation example shown
in this section is a configuration with a
flat ductwork connection on the extract
air side. Various sample configurations
are illustrated in section 9.2.1 and
section 9.2.2.
►
Saw a channel 215 mm wide and
105 mm deep in the upper batten
(item 1 in Fig. 12) for the ductwork
connection adapter on the extract air
side.
►
Saw a channel 118 mm wide and
60 mm deep in the ceiling joist (item 2
in Fig. 12) for the extract air duct.
► Check that the installation kit fits
easily into the space.
►
If necessary, saw channels for the
rest of the flat ductwork as shown in
your plans.
NOTICE
The dimensions of the channels for the
flat ducts are:
— 118 mm wide
— 60 mm deep
The dimensions of the channels for the
flexible pipes are:
— 170 mm wide
— 85 mm deep
Fig. 11: Installation kit with ductwork connection
adapter on the extract air and supply air sides
1
2
Fig. 12:
Sawing channels for flat ductwork or flexible
pipes, dimensions in millimetres
215
60
104
118
104
105
1
2