- 40 -
Installation manual
M-WRG-II M
Meltem Wärmerückgewinnung GmbH & Co. KG
Am Hartholz 4 · D-82239 Alling
[email protected] · www.meltem.com
VENTILATION THE RIGHT WAY
V E N T I L A T I O N & H E A T R E C O V E R Y
9.16
Preparing the installation kit for connecting the ventilation pipes
— Work on the internal wall:
► Remove the signal cover (item 1 in Fig. 38).
► Use a blade to score the plaster on the inside of the plastering trim (item 2 in
► Carefully remove the plaster cover (item 3 in Fig. 38) and the cardboard insert
behind it.
— Work on the external wall:
► Remove the two protective sleeves (item 1 in Fig. 39).
Fig. 38: Installation kit plastered on the inside
1
2
3
Fig. 39: Installation kit plastered on the outside
1