InfiniBand FDR Switch Platform Hardware User Manual
Mellanox Technologies
39
nection between the chassis of the switch and the rack. Test the ground using an Ohm
meter.
Figure 30: Ground Connection
1.8
Power Connections
The switch includes integrated hot-swap power supplies which support up to 6 load-shar-
ing 1000W or 1600W supply units. The slots for the power supply units (PSUs) are on
the spine side. The left side has odd numbered PSUs and the right side has even num-
bered PSUs. Each PSU has a dedicated AC inlet. This design enables the optional use of
separate main and backup AC feeds. The input voltage is Autorange, 100-240 VAC,
50Hz or 60Hz. The output voltage for the PSUs is 48V. The power cords should be stan-
dard 3-wire AC power cords including a safety ground.
1.8.1
Powering Up the Switch Platform
The chassis in N+1 mode must be started with a full complement of PSUs, thereafter it
can run on one less than the total number of PSUs. This final PSU is redundant and
Make sure that the power cords are compatible with your outlets. Power cords for dif-
ferent countries can be ordered from Mellanox.