InfiniBand FDR Switch Platform Hardware User Manual
Mellanox Technologies
57
7. Using only the management ejector handles, slowly slide the board into the chassis
until the hooks reach the vertical bar.
8. Catch the hooks onto the vertical bar of the chassis and push the ejector handle shut.
9. Lock the ejector handles onto the board.
1.10.6 Switch Shut-Down Procedures
To shut down the chassis run the following command twice (once for each MM):
The first time you run the command it shuts down the master management module and
the second time shuts down the slave management module.
To shut down a leaf run the following command:
To shut down a spine run the following command:
To shut down a management module run the following command:
Do not apply excessive force to slide in the management board. If you feel resistance,
remove the management and double check both the chassis and management for any
damage.
On switch systems with dual management systems, first connect the cable and configure
the master management module CPU and only then configure the slave. By default the
master CPU is the top management module. For further information on the master and
slave roles, see the
MLNX-OS®
Software UM section “High Availability”.
All management modules in the chassis must go through an initial configuration proce-
dure. See the Installation Guide for the initial configuration procedure.
Reload halt [noconfirm]
The chassis cannot be restarted remotely!
To restart the chassis you must physically go to the switch and unplug all of the
power cords to the chassis and then replug in all of the power cords to the chas-
sis.
no power enable <module>
no power enable <module>
no power enable <module>