InfiniBand Switch Platform Hardware User Manual
Mellanox Technologies
54
ical connection is made the LED will change to green. When data is being transferred the
light will blink green.
2.1.3
Spine Board LED Indicators
Each leaf board is connected by links to each spine module. Each spine has the following
LEDs.
•
One status LED for the spine health
•
One status LED for the spine fan modules
•
36 status LEDs showing the existence of leaf to spine connections
The 36 LEDs on each spine are divided by the number of leafs and the result (N) is the
number of connections from each leaf that are connected to the spine. 6 spines must be
installed and working to ensure that full BW exists between nodes. The maximum num-
ber of connections from each leaf is 3. If the (number of leafs) x (the maximum number
of connections per leaf) is less than 36 then some of the leaf to spine connection LEDs
may be OFF.
The status LEDs for the spine and their descriptions are shown in Table 5. The LEDs
indicate as follows.
Figure 46: Spine Status LEDs
2.1.3.1 Status LED
Table 5 shows the spine status according to the LED condition.
The switch does not provide a visual means to indicate the port speed configuration
(SDR, DDR, QDR) and/or the link width (1X or 4X). The speed and link width config-
urations can be retrieved using management software.
Table 5 - Spine Status LED
LED Condition
LED Description
Off
No power to the spine
Solid Green
Spine is up and running
Flashing Green
Spine is powering up
Solid Orange
Non fatal error – this spine needs troubleshooting, but does not
require chassis shutdown
Solid Red
Fatal error
1
3 5
9 11
2
4 6
8 10 12 14 16 18
17
15
13
7
35
33
31
27
25
36
34
32
30
28
26
24
22
20
19 21 23
29
Status
Fan Status
Spine leaf IB connection status
Spine Status
Fan Status