Figure: Menu Tab "IRIG Out" Selection of the IRIG code (IRIG DCLS only)
Figure: Menu Tab "Prog. Out" Selection of the signal option for the programmable pulse output (PPO)
The following programmable pulse outputs can be selected:
Idle
(not in use)
Timer
(3 switching-times On - Off)
Single Shot
(pulse length and start time)
Cyclic Pulse
(pulse length and cycle time)
Pulse Per Second
(pulse length)
Pulse Per Minute
(pulse length)
Pulse Per Hour
(pulse length)
DCF77 Marks
(timeout)
Position OK
(position determined)
Time Sync
(clock synchronized)
All Sync
(position determined and clock synchronized)
DCLS Time Code
Synthesizer Frequency
126