RedHand Scope60MHz
Handheld DSO & DMM
7-Advanced Function of Oscilloscope
46
7.6 Acquiring Mode Setting
The
Acquiring Mode
menu
is described in the list shown as below.
Function menu Settings
Description
Sampling
Normal sampling mode.
Peak Detection
Used to detect the jamming glitch and reduce the possible
blurring.
Average value
Used to reduce the random and unrelated noises. Several average
factors are available for being selected.
Average factor
4, 16, 64
or 128
Select the average factor.
7.7 Display Setting
The
Display Setting
menu is described in the following table.
Function menu Settings
Description
Type
Vector
Dot
The vector is filled up spaces between neighboring sampling
points in the display.
Only sampling points are displayed.
Persistence
Close
1s
2s
5s
Infinite
Setting persistence time for each sampling point.
Display format
YT
XY
Display the relative relationship between vertical voltage and
horizontal time.
Display CH1 on the horizontal axis and CH2 on the vertical axis.
Communication
Bitmap
Vector
The data transmitted in communication are bitmaps.
The data transmitted in communication are vectors.
7.7.1 Display Style