9018116 

 

 

 

 

Information on instructions for use 

 

Before using the machine, read the instructions for use and the related documents 
carefully and keep them in a safe place and within easy reach.  

These instructions for use can be downloaded from the following address: 
https://www.meiko.de and https://www.meiko.info or https://partnernet.meiko-
global.com. 

 

1.1 

Product identification 

 

These instructions for use apply to the following machine type: 

Cleaning and disinfection machine 

TopClean M, M2 type. 

 

1.2 

Delivery contents 

 

The delivery contents include: 

•  1x TopClean M cleaning and disinfection machine 
•  Connection hoses for fresh water and waste water 
•  Documentation 

Optionally available: 

•  Racks, as per rack range 

 

1.3 

Related documents 

 

The following documents provide additional information to these instructions for use: 

•  Installation drawing 
•  Wiring diagram 
•  Installation instructions for optional components (e.g. GiO MODULE) 
 

External documents of the manufacturer of the respiratory protective equip-
ment 

•  Current washing instructions 
•  Current release 

 

 

 

 

Liability and warranty 

 

All of the manufacturer's obligations arise from the relevant purchase contract, which 
also contains the entire and only valid guarantee provisions. These contractually 
guaranteed provisions shall be neither extended nor restricted as a result of any ex-
planations given in the instructions. 

 

If you follow these operating instructions for use, your washer-disinfector will always 
work to your complete satisfaction and have a long service life. 

The delivered device corresponds to the state of technology and safety regulations 
valid at the time of production/delivery. 

The information, data and notes specified in the instructions for use correspond to 
the latest version at the time of printing. No claims for already delivered systems 
may be asserted based on these statements, illustrations and descriptions. 

 

Claims must be reported to the manufacturers immediately after determination of the 
defect or error.  

 

 

Summary of Contents for TopClean M

Page 1: ...m 2018 12 Update 2021 09 www meiko info Read the instructions for use before using the appliance test TopClean M Type M2 Cleaning and disinfection machine for respira tory protection equipment Instruc...

Page 2: ...3 GiO MODULE 13 4 4 Blue operating concept 14 4 5 Detergent and rinse aid 14 4 5 1 Detergent 15 4 5 2 Rinse aid 15 4 5 3 Dosing equipment 15 4 5 4 Suction lances 15 4 5 5 Change of products 15 4 6 Che...

Page 3: ...e 34 9 4 Decommissioning the cleaning and disinfection machine 35 9 5 Fill consumables 35 9 5 1 Replace canister 36 9 6 Water change programme option 36 9 7 Malfunctions 37 9 7 1 Messages 37 9 8 Chang...

Page 4: ...components e g GiO MODULE External documents of the manufacturer of the respiratory protective equip ment Current washing instructions Current release 2 Liability and warranty All of the manufacturer...

Page 5: ...vents or force majeure 3 Safety Read and observe all safety information instructions and symbols attached on the product Improper use may result in damage to the product or danger to the user 3 1 Symb...

Page 6: ...of the danger of hand injuries Caution keep hands away from parts that bear this warning symbol The danger ex ists that hands can be crushed pulled in or otherwise injured Warning of hot surfaces and...

Page 7: ...her disinfector are supervised by a trained and experienced operator at all times Clearly define the staff s responsibilities Confirm training in writing Persons Experienced staff Instructed in house...

Page 8: ...ye injury health risks Wear safety eyewear gloves Avoid contact with skin and eyes Operation Cleaning programme run ning Scalding due to inappropri ate opening of the wash chamber door Do not open the...

Page 9: ...ive gloves GiO MODULE replace fil ter cartridge Water escaping Provide suitable vessel e g base drip tray Dismantling and disposal Dismantling Eye injury health risks Wear safety eyewear gloves Avoid...

Page 10: ...hine has an obligation of care to ensure that these measures are planned for and also to check that they are correctly implemented The operator must ensure in particular that The cleaning and disinfec...

Page 11: ...disinfection machine may only be operated under the supervi sion of trained personnel Do not use the cleaning and disinfection machine if you are not sure how to use it Always close all doors and fla...

Page 12: ...electronics There is a danger to life if exposed parts and supply lines under electrical voltage are touched Please take note of the warning notices in these instructions and the signs on the cleanin...

Page 13: ...degree of soiling of the rinse water 4 2 Type label The rating plate is on the inside of the front panel Additional rating plates are lo cated on the switch cabinet behind the front panel on the displ...

Page 14: ...eaning and disinfection appliances Generally the currently valid documentation of the PPE manufacturer must be followed when choosing the right cleaning chemicals Deviations from this can lead to a lo...

Page 15: ...on page 42 4 5 3 Dosing equipment The components of the dosing units are subject to high demands and must therefore be regularly maintained and if necessary replaced in accordance with the mainte nan...

Page 16: ...s machine dimensions as well as connection and consumption values Further data should be taken from the MEIKO dimensional drawing Net weights Versions Weight approx UPster U 500 M2 73 kg ActiveClean w...

Page 17: ...note If applicable submit a claim for any missing parts immediately to the freight for warder and notify MEIKO Check the machine for transportation damage Note If there is any suspicion of transportat...

Page 18: ...AB as per EN 1717 or EN 61770 In the case of SVGW Switzerland and other countries a type EA safety device at least is also required in front of the connection hose de pending on the machine version I...

Page 19: ...ly installed protective conductor system It is very important to verify this fundamental safety feature If in doubt have the building wiring checked by an electrician Voltage and frequency The machine...

Page 20: ...e mains switch Mains power cables must be oil resistant shielded flexible cables no lighter than an H07RN F cable Local fuse protection The machine must be fused appropriately for the rated current sh...

Page 21: ...ed only by a licensed and authorised service technician Assembly must be carried out in accordance with the installation drawing Ensure the machine is level in both directions by using a water level C...

Page 22: ...Prerequisites to be provided by the customer Consistently frost free storage and installation area Firm level ground Anti slip floor coverings installed in the work area around the cleaning and dis i...

Page 23: ...ch of the keys and symbols is described below Key symbol Meaning On off key programme termination Cleaning key with control light Control light lit cleaning programme is running Control light flashing...

Page 24: ...t be used without precise knowledge of the instructions for use Incorrect operation may result in personal injury or mate rial damage 1 Ensure water supply is available 2 Switch on at the local mains...

Page 25: ...he selected cleaning programme key flashes The time re quired for the machine to be ready to operate depends on the temperature of the water supply and the installed boiler or tank heating capacity Wh...

Page 26: ...ompressed air connection Combination rack For 4 respirators and 4 regulators at the same time Harness attachment with base rack for 1 harness Rack insert for compressed air bot tles 9 3 2 Accessories...

Page 27: ...9018116 27 54 9 3 3 Placement of respirator masks Lift safety device place inner mask on bracket and se cure Small parts rack with mask utensils...

Page 28: ...28 54 9018116 Hang the mask on the upper sealing edge on a bracket Partially loaded rack Place lid on small parts rack...

Page 29: ...9018116 29 54 9 3 4 Placement of regulators Dismantle the regulator in accord ance with the manufacturer s instruc tions Place individual parts in the small parts rack and close the lid...

Page 30: ...the adapter optional Standard suitable for 40x1 7 round thread detergent dosing unit and ESA plug con nection Option adapter for M 45x3 v thread and industrial plug connection Additional adapters ava...

Page 31: ...9018116 31 54 Note Again if the couplings are not used close them with the protective cap 9 3 7 Placement of harness...

Page 32: ...the programme run the wash chamber door is locked The control light of the selected cleaning programme key lights up Cleaning pro gramme Meaning Washware Short programme Cleaning programme I Exercise...

Page 33: ...rinse time is changed the dosage amount of the rinse aid changes correspondingly 9 3 11 Starting the cleaning process 1 Preclean washware that is very dirty coarse dirt residues etc and insert into t...

Page 34: ...from the compressed air pipe Press the locking button to disconnect the com pressed air pipe Press the locking button again and pull the com pressed air hose out of the coupling 9 3 13 Removing the wa...

Page 35: ...he control light on the cleaning key flashes The cleaning water is pumped out and the tank is sprayed with hot fresh water After the operation has finished the machine automatically switches into OFF...

Page 36: ...water change programme is stored at the cleaning pro gramme key III The cleaning and disinfection machine cleans normally and empties the tank The fresh water final rinse follows The water from the fr...

Page 37: ...shwashing detergent used Do not use a foaming manual dishwashing detergent for precleaning or for cleaning the machine In the cleaning and disinfection machine foam can cause unit malfunctions and a p...

Page 38: ...t wa ter tap closed Feed hose kinked discon nected leaks Inlet filter soiled Solenoid valve defective Boiler switch defective Check water supply Check feed hose Check pre filter sieve and clean if nec...

Page 39: ...pump plug connection open Start capacitor defective Tank level analysis disrupted Aquastop does not close correctly No signal from I O circuit board Not possible to continue working Call a service te...

Page 40: ...Cleaning programme key 1 Increase value by one Cleaning programme key 2 Decrease value by one 1 Press and hold the On Off key for about three seconds 2 Enter the service code for the required authori...

Page 41: ...ys The service level can be departed with the on off key 9 9 2 Ventilating the pipes The ventilation of the detergent disinfectant or rinse pipes must be performed if air is sucked in from the dosing...

Page 42: ...dosing technology are displayed and can be changed Code display Meaning Adjusting range P104 Rinse aid dosing quantity 0 10 1 00 ml L P105 Detergent disinfectant dosing quantity 0 10 20 0 ml L P218 L...

Page 43: ...tenance and repair work This can lead to injuries Only permit qualified persons to perform work at the machine Remove unauthorised persons from the danger zone Cordon off danger zone and signpost it f...

Page 44: ...lters in machines with GiO MODULE must be carried out by trained operators Neglected or improper maintenance increases the residual risk of unforeseen dam age to property and persons for which no liab...

Page 45: ...nctional and visual check of washing and rinse arms Annually Replace sealing rings on wash arms Annually Check air trap of the tank and clean if necessary Annually Check tank level control for leaks A...

Page 46: ...s Annually Check sample rinsing and rinsing results Annually Brief training for new personnel Annually 11 Options Integrated reverse osmosis system if available Visually check whole system for leaks A...

Page 47: ...or dish washing by hand for pre cleaning or clean ing the cleaning and disinfection machine Foam can cause unit malfunctions and a poor wash The machine is emptied see chapter Decommissioning the clea...

Page 48: ...when required the stainless steel surfaces are cleaned exclu sively using cleaning and care products that are suitable for stainless steel Lightly soiled parts can be cleaned with a soft and possibly...

Page 49: ...lator Manually open a gap in the front door or hood to prevent germ formation and odours Frost protection If necessary have the machine frost proofed by the authorised service technician 11 2 Commissi...

Page 50: ...ty data sheets and dosing recommendations of the chemical manufacturers Use eye protection Wear protective gloves Do not mix different chemical products Where appropriate rinse machine components cont...

Page 51: ...50 Disposal of the old device 50 Dosing equipment 15 Dosing system level 15 42 E EC EU declaration of conformity 16 Electrical connection Earth wire system 19 Fixed connection 19 Local fuse protection...

Page 52: ...Requirements for the personnel 7 Requirements for the waste water connection 18 Requirements to the electrical connection 19 Residual risks 8 Rinse aid 15 S Safety 5 Safety symbols in the instructions...

Page 53: ...9018116 53 54 15 Notes...

Page 54: ...Valid from 2018 12 Update 2021 09 MEIKO Maschinenbau GmbH Co KG Englerstra e 3 77652 Offenburg Germany www meiko global com info meiko global com Design and construction subject to change without prio...