4.2.2. Module Shutdown
Users can use the PWRKEY pin to shutdown.
4.2.2.1 PWRKEY Shutdown
The user can turn off the PWRKEY signal by pulling it down for at least 3 seconds. The
shutdown circuit can refer to the design of the boot circuit. After the module detects the
shutdown action, a prompt window pops up on the screen to confirm whether to perform the
shutdown action.
The user can achieve a forced shutdown by pulling PWRKEY down for a long time, pulling
down for at least 15 seconds.
4.2.3.Module Reset
The SLM500 module supports a reset function that allows the user to quickly restart the
module by pulling the
RESET_N
pin
(
225
)
of the module low. The recommended circuit is as
follows:
Figure 4.8
:
Reset using the key circuit
Figure 4.9
:
Reset Module Using External Signal