26
TORKEL 900-SERiES
ZP-CS01E
CS033663DE
5 MAKiNG A TEST
3]
Disconnect the cables in reverse order as
described in section "Connecting the current
cables to the battery" on page 20
WARNING
Do not connect a discharged battery to a
battery that has not been discharged. The
batteries must be charged to the same
potential (voltage) before they are con-
nected together.
5.7 Viewing results and
reporting
Viewing the results
1]
Select the "RESULT" tab to view the test
results
2]
In the RESULT and BATTERY tabs you can add
information by pressing the "Edit" button.
Float voltage
The voltage value prior the charger is
removed.
Open voltage
The value prior start of discharge
test.
Start voltage
The value given after the first initial
decrease of the battery bank at a
start of a discharge test.
End voltage
The value at the end of discharge test
REPORT
The saved test can be stored on an USB memory stick
and transferred to a PC. The included PC software
TORKEL Viewer can be used to edit and print out
reports, see paragraph "4.2 TORKEL Viewer" on page
19.
Summary of Contents for TORKEL 910
Page 2: ......
Page 13: ...CS033663DE ZP CS01E TORKEL 900 series 13 4 Menu system...
Page 27: ...CS033663DE ZP CS01E TORKEL 900 series 27 6 External current measurement...
Page 31: ...CS033663DE ZP CS01E TORKEL 900 series 31 7 Alarm function...
Page 33: ...CS033663DE ZP CS01E TORKEL 900 series 33 8 How to obtain the desired current...
Page 41: ...CS033663DE ZP CS01E TORKEL 900 series 41 10 Troubleshooting...
Page 43: ...CS033663DE ZP CS01E TORKEL 900 series 43 11 Calibration...
Page 45: ...CS033663DE ZP CS01E TORKEL 900 series 45 12 Specifications...
Page 49: ...CS033663DE ZP CS01E TORKEL 900 series 49 12 Specifications...
Page 51: ......