38
TORKEL 900-SERiES
ZP-CS01E
CS033663DE
9 OPTiONAL EQUiPMENT
The other parts of the BVM system: AC Adapter, Power and
Signal Connector and cables.
Power & signal connector unit
The BVM units require external 24 DC power and RS-
485 data communications for operation. These func-
tions are provided by a combination of an external DC
power supply and a Power & signal connector unit”.
The Power & signal connector conversion is performed
within a single moulded plug that connects directly to
the laptop computer or other data acquisition device.
The Power & signal connector has an RJ-45 connector
that provides a connection to the first BVM unit in the
chain, and this connection provides RS-485 data and
power to all BVM units in the BVM string.
Test with BVM and TORKEL
WARNING
See the chapter "Safety" for safety pre-
cautions.
1]
Connect the BVM units as shown in the con-
nection diagram, see below.
Each BVM is identical and can be connected
in any battery test position. Up to 120 BVMs
can be daisy-chained in a single battery bank
under test.
If you need more than 120 BVMs they must
be connected in two loops, see connection
diagram on next page.
Note
The BVM units must be connected following
the battery cell sequence order. The BVM
connected to the “To 1:st BVM unit” port of
the Power and Signal connector must be con-
nected to the most Negative pole of the bat-
tery. The red dolphin clip shall be connected
to the most Positive pole of the battery. The
connection is the same regardless of the cell
numbering selected in TORKEL.
If more than 61 BVM units are connected
an extra cable is needed. See the connection
diagrams.
Fig.9.1 The BVM units must be connected following the battery cell sequence order. The red dolphin clip shall be connected
to the most Positive pole of the battery.
Summary of Contents for TORKEL 910
Page 2: ......
Page 13: ...CS033663DE ZP CS01E TORKEL 900 series 13 4 Menu system...
Page 27: ...CS033663DE ZP CS01E TORKEL 900 series 27 6 External current measurement...
Page 31: ...CS033663DE ZP CS01E TORKEL 900 series 31 7 Alarm function...
Page 33: ...CS033663DE ZP CS01E TORKEL 900 series 33 8 How to obtain the desired current...
Page 41: ...CS033663DE ZP CS01E TORKEL 900 series 41 10 Troubleshooting...
Page 43: ...CS033663DE ZP CS01E TORKEL 900 series 43 11 Calibration...
Page 45: ...CS033663DE ZP CS01E TORKEL 900 series 45 12 Specifications...
Page 49: ...CS033663DE ZP CS01E TORKEL 900 series 49 12 Specifications...
Page 51: ......