44
TORKEL 900-SERiES
ZP-CS01E
CS033663DE
11 CALiBRATiON
11
C
alibration
11.1 General
By using the internal calibration program TORKEL will
be calibrated on internal/external current and internal/
external voltage. However, external instruments must
be used.
▪
Stable voltage power supply (vary less than 1% per
second) with capability up to 200 V DC.
▪
Current source (vary less than 1% per second)
supplying
upp to 100 A DC at a voltage between 10 and
30 V DC
, e.g. a 12 V car battery can be used.
▪
Accurate reference instrument, e.g. HP 34401A, must be
used.
▪
A current shunt with accuracy class 0.1% for connection
in series with the current source.
11.2 How to calibrate
1]
Switch on TORKEL.
2]
Press
button to enter the configura-
tion menu.
3]
Press “Calibration” tab.
4]
Press “Start” and follow on-screen instruc-
tions.
WARNING
Follow the instructions carefully. Battery
connectors may have dangerous voltage
Note
You can press “Skip” to continue to the next
calibration step. No value will be added.
Press “Previous” to redo a calibration point.
5]
Press "Store" to save the calibration values.
Note
If the “Skip” button is pressed the calibration
values will not be saved.
6]
Connect an USB stick to save a copy of the
calibration report that can be opened with
Excel.
7]
Press "Stop" to stop the calibration and leave
the calibration routine.
The fans will start and run for about 10 sec-
onds.
Summary of Contents for TORKEL 910
Page 2: ......
Page 13: ...CS033663DE ZP CS01E TORKEL 900 series 13 4 Menu system...
Page 27: ...CS033663DE ZP CS01E TORKEL 900 series 27 6 External current measurement...
Page 31: ...CS033663DE ZP CS01E TORKEL 900 series 31 7 Alarm function...
Page 33: ...CS033663DE ZP CS01E TORKEL 900 series 33 8 How to obtain the desired current...
Page 41: ...CS033663DE ZP CS01E TORKEL 900 series 41 10 Troubleshooting...
Page 43: ...CS033663DE ZP CS01E TORKEL 900 series 43 11 Calibration...
Page 45: ...CS033663DE ZP CS01E TORKEL 900 series 45 12 Specifications...
Page 49: ...CS033663DE ZP CS01E TORKEL 900 series 49 12 Specifications...
Page 51: ......