Output Voltage (max.)
OTS60AF/2
60 kV (30 kV - 0 - 30 kV)
OTS80AF/2
80 kV (40 kV - 0 - 40 kV)
OTS100AF/2
100 kV (50kV - 0 - 50 kV)
(high voltage test frequency is 61,8 Hz)
Display
Dot-matrix liquid crystal display giving alphanumeric information
and kV test voltage.
Resolution
0,1 kV
Temperature Range
Operating
0
°
C to +40
°
C
Storage
-40
°
C to +70
°
C (in accordance with BS 2011 part 2)
Humidity Range
Operating
80% RH at 40
°
C (non-condensing)
Storage
93% RH at 40
°
C, 95% RH at 25
°
C (in accordance with BS 2011
part 2 )
External Printer Socket
9 pin ‘D’ type plug for RS232C interface
Safety
The test sets meet the requirements IEC 61010-1
E.M.C.
In accordance with IEC 61326-1
Operational uncertainties
Refer to www.megger.com
Supply Voltage
220 V ± 10%, 240 V ± 10%,
110 V ± 10%, 120 V ± 10%,
(four selectable values), 50 Hz / 60 Hz.
Fuses
2 x 6,3 A (F) ceramic HBC IEC 127/1, 20 mm x 5 mm
3.15 A (T) ceramic HBC IEC 127/5, 20 mm x 5 mm, for 220 V /
240 V
4 A (T) ceramic HBC IEC 127/5, 20 mm x 5 mm, for 110 V/120 V
Mains power cord fused plug: 13 Amp fuse to BS 1362
Dimensions
502 mm x 464 mm x 319 mm (19
3
⁄
4
in x 18
1
⁄
4
in x 12
1
⁄
2
in approx.)
Weight
41 kg (90 lb) approx.
Cleaning
Wipe disconnected test set with a clean cloth dampened with
Isopropyl Alcohol (IPA)
Specification