4. First use set up of the EVCC300 and setting
4.1 Turning the instrument on and off
1. To turn the EVCC300 ON press and hold softkey (1).
2. To turn the EVCC300 OFF press and hold softkey (1).
Before use it is important that the EVCC300 is set up correctly. The following the appropriate supply settings.
There are four options as follows:
1. 230 V, 1 Ph (EU / UK)
2. 120 V, 1 Ph (US)
3. 208 V, 2 Ph (US)
4. 240 V, 2 Ph (US)
Once the initial supply settings have been set the settings will be accessed in the order shown below in section c.
4.2 Battery options
The EVCC300 operates from four alkaline AA battery cells.
Warning: DO NOT use rechargeable batteries in the EVCC300
4.3 Settings
4.3.1 Direct or via cable charger connection setting
The EVCC has the capability to detect and test the proximity and latched status of the connection to the charger. To
be able to achieve this the instrument will need to know whether it is plugged into a charger directly or via a tethered
or connection cable.
When selecting settings the EVCC300 will allow the user to toggle between charger connection method:
1. Press softkey 1 or 3 (arrows) to highlight the desired setting
2. Press softkey 2 to SELECT. When the required connection
method is selected the EVCC300 will immediately return to
the main menu screen.
or
3. Select softkey 3 (NEXT) to advance to the next setting screen,
Supply Settings.
This will allow a rapid change of connection method while
testing. In the main menu screen there is an indicator in the top
left of the screen.
In this example of a menu screen the EVCC300 is set to direct
connection. If the red cross is not present the instrument is set
for connection to the charger via a tethered cable or plug in
charging cable.
10
First use set up of the EVCC300 and setting