ALWAYS CHECK FOR LEAKS AFTER EVERY LP GAS CYLINDER CHANGE
Check all gas supply fittings for leaks before each use. It is handy to keep a spray bottle of soapy
water near the shut-off valve of the gas supply line. Spray all the fittings. Bubbles indicate leaks.
CAUTIONS
Place dust cap on cylinder valve outlet when the cylinder is not in use. Only install the type of dust
cap on the cylinder valve outlet that is provided with the cylinder valve. Other types of caps or plugs
may result in leakage of LP gas.
The gas must be turned off at the supply cylinder when the unit is not in use.
If the appliance is stored indoors the cylinder must be disconnected and removed from the
appliance. Cylinders must be stored outdoors in a well-ventilated area out of the reach of children.
Your grill is ready to use!
22
GENERAL
Although all gas connections on the grill are leak tested at the factory
prior to shipment, a complete gas tightness check must be performed
at the installation site due to possible mishandling in shipment, or
excessive pressure unknowingly being applied to the unit.
Periodically check the whole system for leaks following the
procedures listed below. If the smell of gas is detected at anytime you
should immediately check the entire system for leaks.
BEFORE TESTING
Make sure that all packing material is removed from the grill including
tie-down straps.
DO NOT SMOKE WHILE LEAK TESTING. NEVER PERFORM LEAK TEST WITH AN OPEN FLAME.
Make a soap solution of one part liquid detergent and one part water. You will need a spray bottle,
brush, or rag to apply the solution to the fittings. For the initial leak test, make sure the LP gas cylinder
is 80% full.
TO TEST:
1. Make sure the control valves are in the “OFF” position, and turn on the gas supply.
2. Check all connections from the LP gas regulator and supply valve up to and including the connection
to the manifold pipe assembly (the pipe that goes to the burners). Soap bubbles will appear where
leak is present.
3. If a leak is present, immediately turn off the gas supply and tighten the leaky fittings.
4. Turn the gas back on and recheck.
5. Should the gas continue to leak from any of the fittings, turn off the gas supply and contact customer
service at (+27) 12 802 1515 .
LEAK TESTING
Summary of Contents for 200 Fusion
Page 1: ...200 FUSION TABLE TOP BRAAI ASSEMBLY OPERATING INSTRUCTIONS...
Page 15: ...15 COMPONENT VIEW...
Page 18: ...17 PUTTING IT ALL TOGETHER...
Page 19: ...18 PUTTING IT ALL TOGETHER...
Page 20: ...19 PUTTING IT ALL TOGETHER...
Page 36: ...200 FUSION TABLE TOP BRAAI ASSEMBLY OPERATING INSTRUCTIONS...