Fig. 1
TO DISCONNECT THE LP GAS CYLINDER:
1.
Turn the burner valves off.
2. Turn the cylinder valve off fully (turn clockwise to stop).
3. Detach the regulator assembly from the cylinder valve by turning the wheel clockwise.
21
NEVER CONNECT AN UNREGULATED GAS SUPPLY LINE TO THE APPLIANCE.
USE THE REGULATOR/HOSE ASSEMBLY SUPPLIED.
This is a LP gas configured grill. Do not attempt to use a natural gas supply, the grill has not been approved
for natural gas use.
Total gas consumption (per hour) with all burners set on “HIGH”:
Main Burner: 13000 BTU/Hr.
LP GAS cylinder REQUIREMENT (9kg. Cylinder)
A dented or rusty LP gas cylinder may be hazardous and should be checked by your LP gas supplier.
Never use a cylinder with a damaged valve. The LP gas cylinder must be constructed and marked in
accordance with the specifications for LP gas cylinders for South Africa.
Storage of an outdoor cooking gas appliance indoor is permissible only if the cylinder is disconnected and
removed from the outdoor cooking gas appliance. The cylinder system must be arranged for vapor
withdrawal. The cylinder must include a collar to protect the cylinder valve.
Remove the plastic valve cover from the LP gas cylinder. Make sure the grill gas hoses do not contact the
grease pan or grill firebox when the LP gas cylinder is placed into the cart.
Regulator Connection
1.
Make sure cylinder valve is in the complete off position
(turn clockwise to stop)
2.
Check cylinder valve to ensure it has proper internal female threads.
3.
Make sure all burner valves are in their off position.
4.
Inspect valve connections, port, and regulator assembly. Look for any damage or debris.
Remove any debris. Inspect hose for damage. Never attempt to use damaged or obstructed equipment.
See your local LP gas dealer for repair.
5.
When connecting regulator assembly to the valve, hand tighten the wheel connection anti-clockwise to a
complete stop. Do not use a wrench to tighten. Use of a wrench may damage the wheel and result in a
hazardous condition.
CONNECTING THE LP GAS CYLINDER
Your grill is equipped with gas supply orifices for use only with LP gas. It is
also equipped with a high capacity hose/regulator assembly for connection to
a standard 9kg. LP gas cylinder 52cm high, 30cm diameter. To connect the
LP gas supply cylinder, please follow the steps below:
6.
Open the cylinder valve fully (counterclockwise). Apply the soap solution with a clean brush to all gas
connections (See Fig. 1). If growing bubbles appear in the solution the connection is not properly sealed.
Check each fitting and tighten or repair if necessary.
7.
If you have a gas connection leak you cannot repair, turn gas OFF at supply cylinder, disconnect fuel line
from your grill and call (+27) 12 802 1515 or your gas supplier for repair assistance. in case of severe gas
leaks or fie, contact your local fire department.
8.
Also apply soapy solution to the cylinder seams. See below. If growing bubbles appear,
shut cylinder OFF and do not use or move it! Contact an LP gas supplier or your fire
department for assistance.
GAS HOOK-UP
Summary of Contents for 200 Fusion
Page 1: ...200 FUSION TABLE TOP BRAAI ASSEMBLY OPERATING INSTRUCTIONS...
Page 15: ...15 COMPONENT VIEW...
Page 18: ...17 PUTTING IT ALL TOGETHER...
Page 19: ...18 PUTTING IT ALL TOGETHER...
Page 20: ...19 PUTTING IT ALL TOGETHER...
Page 36: ...200 FUSION TABLE TOP BRAAI ASSEMBLY OPERATING INSTRUCTIONS...