Appendix
89
14.4.2 Wrong system - vacuum suction system
If the wrong software was updated, the message
wrong system
is displayed.
In this case follow please exactly the guidance below.
1.
switch OFF
the boiler at the main switch
2.
unplug the plug
ES BSK
at the boiler controller (CMP)
3.
switch ON
the boiler
4.
go to
Code input
5.
push the button
Enter
6.
enter the
Code
7.
push the button
Enter
8.
go to
Pellematic
9.
push the button
Enter
10. go to
Pellematic CMP
11. push the button
Enter
12. go to
Update
13. push the button
Enter
14. select the file US_
VA
15. push the button
Enter
16. if
Progress successful
is displayed – push the button
Enter
Note:
The message
Wrong system
is displayed again – that`s o.k.
PE 3671 USA 2.3
Installation Manual PES 36–56