page 26
To disable the AV/TIME function, press the
ENTER
key
when the cursor arrow is aligned with ON in AV/TIME
sub-menu 1. It will now display OFF.
Press the
ESC
key to return to the main menu page 1,
and again to return to the main display.
The maximum duration of AV/TIME calculation is
approx. 22 minutes. When the time limit expires, ‘AT’ is
displayed in the main display, and the
MAX
key must be
pressed in order to clear ‘AT’ and continue use of the
AFG.
This function allows the selection of the gauge data
capture rate, i.e. the amount of averaging performed
by the internal electronics before the load reading is
displayed. Data are sampled at 5000Hz and averaged to
2 levels.
MEDIUM
80Hz (Default)
HIGH
2000Hz
To set RATE, press and hold the
MENU
key until the
main menu page 1 appears. Press and release the
MENU
key to access the main menu page 2. Using the
UP
and
DOWN
keys move the arrow cursor to RATE,
and press
ENTER
.
Using the
UP
and
DOWN
keys select the relevant level
(MEDIUM or HIGH) and press the
ENTER
key.
Press the
ESC
key to return to the main menu page 2,
and again to return to the main display.
MAIN MENU PAGE 2
RATE
RATE sub-menu 1
Fig. 11
Main menu page 2