Monitoring of System Functions and Integrity
In case a failure is detected in one or more of the following functions or data, an alarm will be
triggered and displayed on the menu-tree under Alarm List, and the system (transponder) will
react as described in the following table.
Alarm's description text
Alarm
ID
Reaction of the system
(transponder)
AIS: Tx malfunction
001
Stop transmission
AIS: Antenna VSWR exceeds limit
002
Continue operation
AIS: Rx channel 1 malfunction
003
Stop transmission on affected channel
AIS: Rx channel 2 malfunction
004
Stop transmission on affected channel
AIS: Rx channel 70 malfunction
005
Continue operation
AIS: general failure
006
Stop transmission
AIS: UTC sync invalid
007
Continue operation using indirect or
semaphore synchronisation
AIS: MKD connection lost
008
Continue operation
AIS: internal / external GNSS position
mismatch
009
Continue operation
AIS: NavStatus incorrect
010
Continue operation
Heading sensor offset
011
Continue operation
AIS: active AIS SART
014
Continue operation
AIS: external EPFS lost
025
Continue operation
AIS: no sensor position in use
026
Continue operation
AIS: no valid SOG information
029
Continue operation using default data
AIS: no valid COG information
030
Continue operation using default data
AIS: Heading lost/invalid
032
Continue operation using default data
AIS: no valid ROT information
035
Continue operation using default data
B.2
Antenna VSWR Exceeds Limit
There is a built-in RF output power detector, which is used to monitor the VSWR of VHF antenna
port. If the antenna VSWR exceeds limit, an alarm will be reported while the unit operates
continuously. The system will output an ALR 002 at related PI port.
B.3
Detection of Tx Malfunction
A built-in lock detector (high active) is used to monitor the local oscillator (PLL circuit) of the
transmitter. If the operation of PLL circuit becomes abnormal, a logic low (TX malfunction) will be
sent from the lock detector to notify the system. At the same time, system will also output an ALR
001 at the related PI port.
B.4
Detection of Rx Malfunction
The Smartfind M5 also has 3 built-in lock detectors (high active) to monitor each local oscillator
(PLL circuit) of receiver channel 1, channel 2, and channel 70 respectively. If the operation of PLL
circuit becomes abnormal, a logic low level will be sent from the lock detector to notify the system.
At the same time, the system will output ALR 003 or ALR 004 or ALR 005 at the related PI port to
indicate the CH1 or CH2 or CH70 RX malfunctions respectively.
Summary of Contents for 21-100-001A
Page 1: ......
Page 2: ...2 ...
Page 3: ...3 Smartfind M5 Class A Inland AIS Installation and Maintenance Manual ...
Page 12: ...12 2 3 Interconnection Diagram Figure 1 Interconnection Diagram ...
Page 81: ...81 6 MECHANICAL DIMENSIONS 6 1 Smartfind M5 Transponder Main Unit Front size mm Side size mm ...
Page 82: ...82 Back size mm Bottom size mm ...
Page 83: ...83 6 2 Junction Box 6 3 Extension Cable 6 4 Mounting Template not to scale 85 mm 55 mm 165 mm ...
Page 84: ...84 6 5 GPS Antenna 6 6 Pilot Plug 2 m 60 mm 40 mm 60 mm 80 mm 103 92 mm ...
Page 112: ...112 Note ...
Page 113: ...113 21 135 001N Issue 15 ...
Page 114: ......