Page 18
Description :
If enabled, this function will allow AC
Mains Fail reporting
Options : (Single digit entry required)
0 -
AC Mains Fail reporting disabled
1 -
AC Mains Fail reporting enabled
Example : While in program mode (Program LED flashing)
Key
Sequence
Operation
77
- Enter
Function
No.
0
-
Enter Option ( 0 = AC Mains Fail Reporting disabled)
On
- Store
Entry
Installer may now exit program mode by pressing the OFF button or continue programming by
entering a new function number.
Function 77 - Report AC Mains Fail
Default - Enabled
Note:
When Mains Fail reporting is disabled, the AC fail detect is also disabled, this means the power led
will not flash when there is no AC power
Description :
This function sets how long the strobe
will be active after an alarm is generated
Note :
When disabled 0 the strobe output will
remain active until the system is dis-
armed.
Options : (Single digit entry required)
0 -
Disabled ( Strobe stays on till disarmed)
1 -
5 min
2 -
10 min
3 -
30 min
4 -
1 hr
5 -
2 hrs
6 -
3 hrs
7 -
6 hrs
8 - 12 hrs
9 -
24 hrs
Example : While in program mode (Program LED flashing)
Key
Sequence
Operation
78
- Enter
Function
No.
2
-
Enter Option ( 2 = Strobe Timeout 10 minutes)
On
- Store
Entry
Installer may now exit program mode by pressing the OFF button or continue programming by
entering a new function number.
Function 78 - Strobe Timeout
Default - Disabled
Function 76 - Multi-Report (Multi-Break)
Default - None
Example : While in program mode (Program LED flashing)
Key
Sequence
Operation
76
- Enter
Function
No.
01
-
Enter Option (01 = sector 1)
02
-
Enter Option (02 = sector 2)
On
- Store
Entries
Installer may now exit program mode by pressing the OFF button or continue
programming by entering a new function number.
Note:
This option will not give multi triggering of sirens to a section but will give multi reporting. The sec-
tion LED will latch on the first alarm for that section.
Description :
Display and change which sections will
report input condition changes when
armed.
Options : (Two digit entry required per sector)
Any sector or combination of sectors from 1 to 8