Page 10
Options - (Single digit entry required)
0 - 0 seconds
5 - 50 seconds
1 - 10 seconds
6 - 60 seconds
2 - 20 seconds
7 - 70 seconds
3 - 30 seconds
8 - 80 seconds
4 - 40 seconds
9 - 90 seconds
Options - (Single digit entry required)
0 - 0 seconds
5 - 50 seconds
1 - 10 seconds
6 - 60 seconds
2 - 20 seconds
7 - 70 seconds
3 - 30 seconds
8 - 80 seconds
4 - 40 seconds
9 - 90 seconds
Options - (Single digit entry required)
0 - 0 seconds
5 - 2 min 40 sec
1 - 10 seconds
6 - 5 min
2 - 20 seconds
7 - 10 min
3 - 40 seconds
8 - 21 min
4 - 80 seconds
9 - 42 min
Description :
This function sets the time that sectors allo-
cated as entry/exit (Function 49), exit hando-
ver (Function 50) or partial exit/entry (Function
51) will allow for exit.
Description :
This function sets the time that sectors allo-
cated as entry/exit (Function 49), exit hando-
ver (Function 50) or partial exit/entry (Function
51) will allow for entry.
Notes :
Handover sectors will only have entry time if
an exit/entry sector has been triggered first
Description :
This function sets the maximum time for which
the internal, external and satellite sirens and
bell output will operate.
Notes:
Australian Standards AS 2201 limit the sirens to be triggered only once per section unless manually re-armed.
Noise pollution regulations in limit siren time to 5 minutes.
Example : While in program mode (Program LED flashing)
Key
Sequence
Operation
40
- Enter
Function
No.
5
-
Enter Option ( 5 = 50 seconds)
on
- Store
Entry
Installer may now exit program mode by pressing the OFF button or continue
programming by entering a new function number
Function 41 - Entry Time
Default - 30 seconds
Example : While in program mode (Program LED flashing)
Key
Sequence
Operation
41
- Enter
Function
No.
3
-
Enter Option (3 = 30 seconds)
on
- Store
Entry
Installer may now exit program mode by pressing the OFF button or continue programming.
Example : While in program mode (Program LED flashing)
Key
Sequence
Operation
42
- Enter
Function
No.
6
-
Enter Option (6 = 5 minutes)
on
- Store
Entry
Installer may now exit program mode by pressing the OFF button or continue programming
Function 42 - Siren Time
Default - 5 minutes
Function 40 - Exit Time
Default - 60 seconds