Page 15

 

Description :
This function determines the format the 
dialler will report in. 

Description :
The dialler will normally report when an 
input is restored to a non alarm 
condition.

Description :
This function programs the number of 
24hr periods between test reports, 
programming a 0 gives no test reports.

Function 67 - Reporting format 

 

 

 

Default - Contact I.D. (4)

Example : While in program mode (Program LED flashing)

 Key 

Sequence 

   Operation 

  69 

 -  Enter 

Function 

No.

 

 

 

 

Enter Option (7 = 7 days)

  On 

 -  Store 

Entry

Installer may now exit program mode by pressing the OFF button or continue 
programming by entering a new function number.

Function 69 - Test reports 

   

        Default - 7 days

Example : While in program mode (Program LED flashing)

 Key 

Sequence 

   Operation 

  68 

 -  Enter 

Function 

No.

 

 

 

 

Enter Option (1 = Report Restorals)

  On 

 

 -  Store 

Entry

Installer may now exit program mode by pressing the OFF button or continue programming 
by entering a new function number.

Option : (Single digit entry required)

Ademco high speed

Tape Dial (No handshake to start Tx.)

SMS reporting (ph # 1,2,3) (Version 8.02+)

4       

Contact I.D. single account number.

GSM Only (PSTN isn't used)

GSM Backup (PSTN primary)

Options : (Single digit entry required)

Report restorals

0      

Do not report restorals

Options : (Single digit entry required)
1 to 7 = period in 

days 

(0 disabled)

8 = 

4hr

 test report

9 = 1hr test report

Function 68 - Report restorals

 

 

 

 

Default - Report  restorals

Notes:

In GSM only mode, the panel will make 3 attempts on the primary via GSM and 3 attempts on the
secondary. There is no 5 minute between primary and secondary attempts during GSM only mode.
In GSM backup mode, the panel will make 3 attempts on the primary via PSTN then 3 attempts on the pri-
mary via GSM...If unsuccessful the panel will wait 5 minutes...then make 3 attempts on the secondary via 

PSTN.  then make 3 attempts on the secondary via GSM. If the line has failed during the first dial attempt of 

the primary it will immediately dial via GSM. If unsuccessfull, it will follow the normal dialing sequence for the 
secondary irrespective of whether the line has failed, and so it will begin dialing via the PSTN. ie the lines ok 
(PSTN,GSM,PSTN,GSM), if the line has failed (GSM,PSTN,GSM)

When selected Tape Dial mode causes the dialler not to listen for acknowledge tone and starts sending alarm 
message continuously for 30 seconds or until a kissoff tone. (In this mode a kissoff tone can be a whistle.) If 

the whistle is received on the first call it will not continue to dial. In this mode no open/closing report, restores, 

isolate/de-isolates, mains fail, low battery or 24 hour test messages are sent.

Example : While in program mode (Program LED flashing)

 

Key 

Sequence 

   Operation 

  67 

  - Enter 

Function 

No.

 

 

 

 

Enter Option (0  =  Ademco high speed)

  On 

  - Store 

Entry

Installer may now exit program mode by pressing the OFF button or continue programming by entering a new 
function number.

Summary of Contents for iRIS8+

Page 1: ......

Page 2: ...ction 67 new options 2 5 and 6 are for GSM and SMS reporting Function 69 new options to enable more frequent test reports Function 89 Single digit arming now sends CID quick arm code 408 Function 91 options 1 and 2 now flashes strobe as well Function 93 the new keyswitch input can now be individually programmed New Functions Function 66 SMS phone number 3 version 8 02 Function 72 line fail reporti...

Page 3: ...Page 3 ...

Page 4: ...istor which limits the charge current Charging voltage to approx 13 7v Bell1 Output timed to DC screamers fused via INT PTC fuse May also be programmed via Function 91 as armed 24 hr alarm bell or to power to latching smoke detectors These then can be reset by User Code Test 6 Bell2 Output timed to drive DC screamers fused via INT electronic auto resetable PTC fuse This bell2 output is not program...

Page 5: ...ction 98 is 0 Do not retain the On Off status the unit starts off in OFF mode and the sirens may operate for half a second If Function 98 is 1 Retain On Off status and the unit was armed when power was interrupted then when power is restored the unit will allow a settling time of 60 secs and attempt to re arm Sectors unsealed after the settling time will be automatically isolated and will be repor...

Page 6: ...xiliary Pause Example For this example Function 60 is already programmed as 0199 If you wish to check Function 60 Enter the function number 6 0 followed by the TEST key whilst in program mode ON LED will light accompanied by a beep digit 0 Then number 1 LED accompanied by a beep digit 1 Then PARTIAL LED accompanied by a beep digit 9 Then another beep with PARTIAL LED still lit digit 9 Then beep be...

Page 7: ...hnician code and press the On key At this point the Program LED will begin flashing to indicate that you are in program mode and the required function number may now be entered If an error was made in entering the code or an incorrect code used the keypad will give a long error beep after which you may try again function number again Program mode will auto exit in approx 10mins Assuming we are in ...

Page 8: ...r inputs 54 Disable sirens on first keypress 55 Silent sections 60 Account number 61 Down Load phone number 63 Open Close reports 64 Phone number one 65 Phone number two 66 Phone Number three SMS reporting 67 Reporting format 68 Report restorals 69 No days between test reports 70 Checksum reporting 71 Report isolates 72 Report line fail 73 Delay till first test report 74 Keypad Duress On Off 75 Au...

Page 9: ...not be able to gain access to program the system func tions Notes 30 User codes may be programmed into the panel These user codes are programmed using function numbers 01 to 30 all are programmed in exactly the same manner No two User Codes may be the same and if Keyboard Duress has been enabled by Function 74 then no two codes can be within 2 digits of each other eg if one code is 1234 then the c...

Page 10: ...cription This function sets the maximum time for which the internal external and satellite sirens and bell output will operate Notes Australian Standards AS 2201 limit the sirens to be triggered only once per section unless manually re armed Noise pollution regulations in limit siren time to 5 minutes Example While in program mode Program LED flashing Key Sequence Operation 40 Enter Function No 5 ...

Page 11: ...it entry required per sector Any sector or combination of sectors from 1 to 8 Function 47 Keypad Remote Panic Audible Default Disabled Example While in program mode Program LED flashing Key Sequence Operation 47 Enter Function No 1 Enter Option Panics now silent On Store Entry Installer may now exit program mode by pressing the OFF button or continue programming by enter ing a new function number ...

Page 12: ...ess Default Disabled 1 Description Display and or change which sections will have exit handover delay Description Display and change which sections will have exit entry delay in Partial mode Description Display and change which sections will operate as 24 hour inputs Example While in program mode Program LED flashing Key Sequence Operation 50 Enter Function No 02 Enter Option Sector 2 becomes hand...

Page 13: ...now exit program mode by pressing the OFF button or continue programming by entering a new function number Function 60 Account number Default None Description Display and change which sections will operate as Silent Sections ie they will report to the monitoring company but will not activate the sirens Description This function is used to enter the account number for transmission to the Central St...

Page 14: ...one number 2 Default None Example While in program mode Program LED flashing Key Sequence Operation 65 Enter Function No 218067 Enter Option Phone number 2 is 218067 On Store Entry Installer may now exit program mode by pressing the OFF button or continue programming by entering a new function number The phone number may be up to 15 digits long including pauses Pauses 1 second may be entered anywh...

Page 15: ...eport Function 68 Report restorals Default Report restorals Notes In GSM only mode the panel will make 3 attempts on the primary via GSM and 3 attempts on the secondary There is no 5 minute between primary and secondary attempts during GSM only mode In GSM backup mode the panel will make 3 attempts on the primary via PSTN then 3 attempts on the pri mary via GSM If unsuccessful the panel will wait ...

Page 16: ...Do not report isolated sections Function 71 Report Isolated Sections Default Report isolates Example While in program mode Program LED flashing Key Sequence Operation 71 Enter Function No 1 Enter Option 1 report isolated sectors On Store Entry Installer may now exit program mode by pressing the OFF button or continue programming by entering a new function number Function 72 Report Line Fail Defaul...

Page 17: ... program mode by pressing the OFF button or continue program ming by entering a new function number Function 74 Keyboard Duress On Off Default Duress disabled Function 75 Auto Isolate On Off Default Auto Isolate disabled Example While in program mode Program LED flashing Key Sequence Operation 75 Enter Function No 1 Enter Option 1 auto isolation enabled On Store Entry Installer may now exit progra...

Page 18: ...s on till disarmed 1 5 min 2 10 min 3 30 min 4 1 hr 5 2 hrs 6 3 hrs 7 6 hrs 8 12 hrs 9 24 hrs Example While in program mode Program LED flashing Key Sequence Operation 78 Enter Function No 2 Enter Option 2 Strobe Timeout 10 minutes On Store Entry Installer may now exit program mode by pressing the OFF button or continue programming by entering a new function number Function 78 Strobe Timeout Defau...

Page 19: ...n 4 Toggle activates the output when button 4 is pressed and de activates the output when button 4 is pressed a second time 5 Report Fail If after 6 dialling attempts the control panel is unable to send an event to the monitoring enter the output will activate The output will restore after the transmission of a successful message 6 Chime Output activates the output for 750msec when a chime zone pr...

Page 20: ... is initiated a second time Installer may now exit program mode by pressing the OFF button or continue programming by entering a new function number Example While in program mode Program LED flashing Key Sequence Operation 83 Enter Function No 3 Enter 3 isolates keyfob 3 5 Enter 5 isolates keyfob 5 On Store Entry Installer may now exit program mode by pressing the OFF button or continue programmin...

Page 21: ...staller may now exit program mode by pressing the OFF button or continue programming by entering a new function number Description This function will allow sections to trigger the keypad beeper for 1 second when in the disarm state Note Function 80 option 6 can be used to activate the PGM output when a chime section is triggered Chime zones will still sound an alarm when fully or partial armed Fun...

Page 22: ...as being unsealed until it is armed again Option 4 GSM Fail reporting enabled GSM Fail reporting function 87 4 and GSM fail output function 80 8 GSM fail will occur after 5 minutes of no registration after which it will report an E352 to the base station if programmed in function 87 activate the PGM OP5 output if programmed in function 80 The GSM fail algorithm is biased towards its current state ...

Page 23: ...message For eg Only 29 arm dis arm by keyswitch reports would fit in one SMS Vs 42 zone 1 8 alarms restorals If the no of events exceeds that of the buffer then the 2nd and 3rd numbers will receive only the events upto the size of the buffer between 29 42 events In this case the last event in the SMS may be partially incomplete The 1st number is not restricted by the buffer therefore ph 1 will rec...

Page 24: ...NOTE If opening closing reporting is enabled the unit will report a quick arm report code 408 in CONTACT ID format or user 15 with ADEMCO high speed format Example While in program mode Program LED flashing Key Sequence Operation 89 Enter Function No 1 Enter Option 1 single digit arming enabled On Store Entry Installer may now exit program mode by pressing the OFF button or continue programming by...

Page 25: ...tion Default Control Dialler Function 93 Keyswitch Option Default No Keyswitch Example While in program mode Program LED flashing Key Sequence Operation 92 Enter Function No 0 Enter Option 0 Control Dialler On Store Entry Installer may now exit program mode by pressing the OFF button or continue pro gramming by entering a new function number Example While in program mode Program LED flashing Key S...

Page 26: ...the OFF button or continue programming by entering a new function number Notes Downloading can be initiated by one of the three methods listed below 1 Ring Detect The panel will dial back using the download phone number Function 62 if it receives three calls of six rings duration 4 8 within a 90 second period 2 Master code initiated Entering the User Master Code test 8 will cause the panel to dial...

Page 27: ...in program mode Program LED flashing Key Sequence Operation 98 Enter Function No 1 Enter Option 1 Retain status On Store Entry Installer may now exit program mode by pressing the OFF button or continue programming by entering a new function number Description The Technician code is used to set up all functions of the system Tech code can only be used when the system is in the OFF mode Options 6 di...

Page 28: ...ail 352 GSM Fail 406 Cancel by User 407 RF Remote Arm Disarm 408 Quick Arm 409 Open Close by keyswitch 306 Panel Programming changed 309 Battery Test Failure 311 Battery Missing Dead 602 Periodic test report PP Area or Partition Number NNN Section Number or User Number Examples of Reporting Note Checksum is omitted for clarity 1234 18 1 120 00 000 Panic Alarm 1234 18 1 121 00 005 Duress Alarm by u...

Page 29: ...ignal stregnth Arm Disarm Full Arm 1111A Full arm the panel Part Arm 1111P Partial arm the panel Disarm 1111D Disarm the panel Isolate Isolate 1111IA 1 2 3 4 5 6 7 8 Isolates section 1 8 and full arms Isolate 1111IP 1 2 3 4 5 6 7 8 Isolates section 1 8 and part arms Output Control Turn ON PGM OP5 1111O5T Turn on PGM output T Toggle Turn OFF PGM OP5 1111O5T Turn off PGM output T Toggle Note Both up...

Page 30: ...GSM Signal Reg Signal Strength 100 31 Signal Strength Excellent 28 Signal Strength Very Poor 4 Example SMS s received 1111S Invalid Command only 1 asterisk 1112S Invalid User Code 1112 is not programmed in the panel 1111x Invalid Command x is an invalid command 1111S Invalid User Cmd Format has a space after the S command 1111A System Armed by User 1 1111A System Already Armed 1111P System Partial...

Page 31: ...and will not report mains fail or mains fail restoral LINE FAIL Line fail is automatically detected by the control dialler When line fail has been detected for approx 60 seconds the fire FAULT LED on the Keypad will start giving a double flash When the line has restored the fire LED will turn off after 10 seconds If line fail reporting is required program a 1 in function 72 Line fail reporting wil...

Page 32: ...ged Bell1 output to chirp using mini siren strobe combo on disarm V7 70 Added extra checking on GSM modem to ruggedise comms Recalibrated 24hr timer test Changed the word Line to PSTN in status SMS Improved GSM SMS operation Fixed partial arming via SMS with an entry exit open sms response may show tamper unsealed rather than zone 1 or 2 open V7 68 Allowed arming while an entry exit section is ope...

Reviews: