![MCM Electronics iRIS8+ Installer Manual Download Page 6](http://html.mh-extra.com/html/mcm-electronics/iris8/iris8_installer-manual_1755802006.webp)
Page 6
Program
Readback
With the full range of panels there are basically two methods of reading back information that has
previously been programmed. The first method allows information that is serial in format to be read
sequentially ie. phone numbers, while the second method allows all selections to be seen at once
ie. sectors assigned as E/E. These are explained below.
SEQUENTIAL READBACK
Whilst in
PROGRAM
mode, if an option is entered followed by the
TEST
key then that options
setting will be read back using the LEDs on the programmer as follows :
" LED " " INDICATES DIGIT "
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
Partial
9
On
0
Auxiliary
Pause
Example
For this example Function 60 is already programmed as
0199
If you wish to check Function 60
Enter the function number
6 0
followed by the
TEST
key.
( whilst in program mode )
ON
LED will light accompanied by a beep
(digit 0)
Then number
1
LED accompanied by a beep
(digit 1)
Then
PARTIAL
LED accompanied by a beep
(digit 9)
Then another beep with
PARTIAL
LED still lit
(digit 9)
Then beep beep and the
PROGRAM
LED flashing again
(test completed ready for next function).
PARALLEL READBACK
For Functions 31 - 36, 49, 50, 51, 52, 55, 56, 61, 76, 82.
When the function number is entered the previously selected sections will
flash. If at this point the
On
button is depressed no changes will be made
and the program LED will be flashing again.
To de-select a section re-enter that section number and the section LED
will extinguish.
Summary of Contents for iRIS8+
Page 1: ......
Page 3: ...Page 3 ...