Page 25
Options : (Single digit entry required)
0 - Control Dialler
1 - Slave Dialler
Description :
This function, if enabled, will enable the full
arm and part arm keyswitch inputs.
To arm panel into Partial mode ground the
part keyswitch input. To arm panel into Se-
cure mode ground the full keyswitch input.
To disarm panel remove ground.
The keyswitch inputs are normally open
(non-monitored) and do not require a 10K
EOL resistor.
When any keyswitch option is programmed
strobe flashes for arm and disarm are ena
-
bled by default
Options : (Single digit entry required)
0 - No Keyswitch fitted
1 -
Latched Keyswitch ( Full and Part inputs )
2 -
Momentary Keyswitch ( Full and Part inputs )
Function 94 - Siren Speed
Default - medium(6)
When the Slave Dialler option is selected,
inputs are 10k end of line
Description :
This function may be used to vary the
speed of the siren outputs.
Options : (Single digit entry required)
9 (slow) to 1 (fast)
Function 92 - Slave Dialler Option
Default - Control Dialler
Function 93 - Keyswitch Option
Default - No Keyswitch
Example : While in program mode (Program LED flashing)
Key
Sequence
Operation
92
- Enter
Function
No.
0
-
Enter Option (0 = Control Dialler)
On
- Store
Entry
Installer may now exit program mode by pressing the OFF button or continue pro-
gramming by entering a new function number.
Example : While in program mode (Program LED flashing)
Key
Sequence
Operation
93
- Enter
Function
No.
2
-
Enter Option (keyswitch inputs are momentary)
On
- Store
Entry
Installer may now exit program mode by pressing the OFF button or
continue programming by entering a new function number.
Example : While in program mode (Program LED flashing)
Key
Sequence
Operation
94
- Enter
Function
No.
3
-
Enter Option (3 = Faster than default)
On
- Store
Entry
Installer may now exit program mode by pressing the OFF button or continue programming
by entering a new function number.
Description :
If this option is enabled, the panel will, to
all intents and purposes act as a slave
dialler.
The keyswitch inputs will report CONTACT-ID 409 when triggered. They no longer report USER
31 open/close as per previous ICON8 versions.