![McElroy Talon 2000 Operator'S Manual Download Page 98](http://html1.mh-extra.com/html/mcelroy/talon-2000/talon-2000_operators-manual_1754758098.webp)
6 - 3
Special Operation - Stub Ends
Configure Machine for Stub End Fusion
On the Machine Control screen, press the Jaw Configuration button
to change the configuration from 2 + 2 to 3 + 1.
To calibrate the indexer position for 3 + 1:
Å
Navigate to the Indexer Calibration screen.
Å
Open the carriage. Position the indexer so that the facer is between the #1 and #2 jaws.
Å
Touch the facer start position button to move the facer into start position.
If the facer does not move when attempting to move the facer, an interlock is preventing the movement based on the indexers current
calibration. The facer interlock can be disabled to allow the facer to move in between the jaws.
NOTICE:
Disabling machine interlocks will not prevent crashing of components while moving the indexer and its components. Use
care when moving indexer components to prevent accidental crashing and damage.
Å
Press the Calibration Interlock to disable the interlocks.
Å
Close the carriage against the facer stops.
Å
Touch the indexer calibration button.
The indexer is now calibrated to the 3 + 1 carriage.
The interlocks are automatically enabled when leaving the Indexer Calibration screen.